Command List - Panasonic HL-C2 Series User Manual

Ultra high-speed, high-accuracy laser displacement sensor
Hide thumbs Also See for HL-C2 Series:
Table of Contents

Advertisement

Chapter 5 External Communication Control

5-1-3 Command List

Refer to "HL-C2 Series USER'S MANUAL RS-232C Communication Control"
for the details of respective commands.
Item
Installation
Mode
5
Emission
Adjustment
Emission
Adjustment
Area
*1 Subdata section consists of 5 digits (zero suppress is omitted) indicated by decimal.
Command
Code
RMM WMM
1/2
RFB WFB
1/2
a REA WEA
1/2
b REB WEB
5-14
*1
Subdata
Setting value
00000
Diffuse reflection
00001
Specular reflection
00000
Auto
00001
0.04%
00002
0.05%
00003
0.06%
00004
0.08%
00005
0.11%
00006
0.14%
00007
0.18%
00008
0.24%
00009
0.31%
00010
0.40%
00011
0.53%
00012
0.68%
00013
0.89%
00014
1.16%
00015
1.50%
00016
1.95%
00017
2.54%
00018
3.30%
00019
4.29%
00020
5.58%
00021
7.25%
00022
9.43%
00023
12.3%
00024
15.9%
00025
20.7%
00026
26.9%
00027
35.0%
00028
45.5%
00029
59.2%
00030
76.9%
00031
100%
-
00001 to 00512
-