Chapter 5 External Communication Control
8
FORMAT
For RS232C output type OUT1 or OUT2
% E E $
Header
For RS232C output type OUT1&OUT2
% E E $ ± 0 1 2
6 7 8
The measurement value consists of 1-character symbol, 3-digit integral
part (no zero suppress), and 6-digit decimal part.
● Normal response
9
FORMAT
5
% E E $ W
● Abnormal response
10
FORMAT
% E E
Special format 7: Exclusive output format for RS232C output mode
±
0 1 2 3 4 5 6 7 8
3-digit integral part
Measurement value of OUT1 or OUT2
Header
CR
BCC
The normal response communication data for data setting
request is common in all formats.
Header
Command
The abnormal response communication data is common in all
formats.
!
Header Error Code
6-digit decimal part
6 7 8 ± 0 1
3
4 5
OUT1 measurement value
CR
BCC
CR
BCC
5-12
CR
BCC
2
3
4
5
OUT2 measurement value