Chapter 5 External Communication Control
■ Communication Procedures
● Configure communication specifications
1.
Configure communication specifications of HL-C2
The communication specifications of RS-232C on HL-C2 are listed in the
table in "5-1-1 Communication Specifications".
situations.
2.
Configure communication specifications of host device
Read the manuals related to the communication specification of external host
device before setting them.
same as the settings of HL-C2, or set the specifications on HL-C2 according
to the settings on the external host device.
■ Change of Communication Conditions
After changing the settings of communication conditions on baud rate, data
5
length or parity check, make sure to save the new setting values and then
restart the controller to reflect them.
Change the specifications so they will be the
5-4