Panasonic HL-C2 Series User Manual page 53

Ultra high-speed, high-accuracy laser displacement sensor
Hide thumbs Also See for HL-C2 Series:
Table of Contents

Advertisement

I/O terminal block
* Turn off the terminal in case short circuit lasts for more than one
second.
Refer to
Do not connect anything to the reserved terminals; they are connected to the
internal circuit.
Terminal
NPN
PNP
ZS2
Zero set input (for OUT2) ON during short circuit
TM2
Timing input (for OUT2) ON during short circuit
RS2
Reset input (for OUT2) ON during short circuit
(-)
Common (-)
AL2
Alarm output (for OUT2)
ST2
Strobe output (for OUT2)
HI2
Judgment HI output (for OUT2)
GO2
Judgment GO output (for OUT2)
LO2
Judgment LO output (for OUT2)
Reserved
(-)
(+)
Common (-)/Common (+)
M0
M1
Memory change (16 ways)
M2
M3
(-)
Common (-)
"1-4 Connection" for the connection method of terminal block.
2-3
Chapter 2 I/O Terminal Block
Function
*
2