Danfoss VLT Decentral FCD 300 Operating Instructions Manual page 106

Hide thumbs Also See for VLT Decentral FCD 300:
Table of Contents

Advertisement

VLT® Decentral FCD
PNU #
Parameterdescription
302
Digital input, term. 18
303
Digital input, term. 19
304
Digital input, term. 27
305
Digital input, term. 29
307
Digital input, term. 33
308
Term. 53, analogue input voltage
309
Term. 53, min scaling
310
Term. 53, max scaling
314
Term. 60, analogue input current
315
Term. 60, min scaling
316
Term. 60, max scaling
317
Time out
318
Function after timeout
319
Term. 42, analogue output
323
Relay output
327
Pulse Max. 33
328
Pulse Max. 29
341
Term. 46 digital output
342
Term. 46 Max. pulse output
343
Precise stop function
344
Counter value
349
Speed comp delay
PNU #
Parameter description
400
Brake function
405
Reset function
406
Aut. restart time
409
Trip delay overcurrent
411
Switching frequency
413
Overmodulation function
414
Min. feedback
415
Max. feedback
416
Process units
417
Speed PID propor.ampl.
418
Speed PID intergra.
419
Speed PID differentiation time
420
Speed PID diff. amplification limit
421
Speed PID lowpass filter
423
U1 voltage
424
F1 frequency
425
U2 voltage
426
F2 frequency
427
U3 voltage
428
F3 frequency
437
Proc. PID no/inv.
438
Proc. PID anti wind.
439
Proc. PID start frequency
440
Proc. PID start proportional ampl.
441
Proc. PID integration time
442
Proc. PID differentiation time
443
Proc. PID diff. ampl. limit
444
Proc. PID lowpass filter time
445
Flying start
451
Speed PID feedforward factor
452
Controller range
455
Frequency range monitor
456
Brake voltage reduce
Factory setting
Start
Reversing
Reset and coast inverse
Jog
No function
Reference
0.0 V
10.0 V
No function
0.0 mA
20.0 mA
10 sec.
No function
0-I
= 0-20 mA
MAX
No function
5000 Hz
5000 Hz
No function
5000 Hz
Normal ramp stop
100000 pulses
10 ms
Factory setting
Depends on unit type
Manual reset
5 sec.
Off (61 sec.)
4.5 kHz
On
0.000
1500.000
No unit
0.010
100 ms
20.00 ms
5.0
20 ms
par. 103
Par. 104
par. 103
par. 104
par. 103
par. 104
Normal
Active
Par. 201
0.01
Off (9999.99 s)
Off (0.00 s).
5.0
0.02 s
Not possible
100%
10 %
Enable
0
MG.04.B8.02 - VLT is a registered Danfoss trademark
Changes during
4-setup
operation
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
Yes
No
Yes
Yes
Yes
Changes during
4-setup
operation
Yes
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
4 All about FCD 300
Conv.
Data
index
type
0
5
0
5
0
5
0
5
0
5
0
5
-1
6
-1
6
0
5
-4
6
-4
6
-1
5
0
5
4
0
5
0
5
0
7
0
7
0
5
0
6
0
5
0
7
-3
6
Conv.
Data
index
type
0
5
0
5
0
5
0
5
0
6
0
5
-3
4
-3
4
0
5
-3
6
-5
7
-5
7
-1
6
-3
6
-1
6
-1
6
-1
6
-1
6
-1
6
-1
6
0
5
0
5
-1
6
-2
6
-2
7
-2
6
-1
6
-2
6
0
5
0
6
-1
6
0
5
0
5
103