Cable lengths and cross sections:
Max. motor cable length, screened/armoured cable
Max. motor cable length, unscreened/unarmoured cable
Max. cross section to motor, see next section.
Max. cross section to control wires, rigid wire
Max. cross section to control cables, flexible cable
Max. cross section to control cables, cable with ferrules
Max. cross section extra terminals for 24 V ext, T73 version, rigid cables
Max. cross section extra terminals for 24 V ext, T73 version, flexible cable
Max. cross section extra terminals for 24 V ext, T73 version, cable with ferrules
Max. cross section PE
Max. cross section external PE for T73 version
If UL/cUL is to be complied with, cable with temperature class 60/75°C must be used. Use copper wires only.
When complying with EN 55011 1A the motor cable must be screened/armoured. See EMC emission.
Control characteristics:
Frequency range
Resolution of output frequency
Precise start/stop
Repeat accuracy of
System response time (terminals 18, 19, 27, 29, 33)
Speed control range (open loop)
Speed control range (open loop) <1.1 kW
Speed control range (closed loop)
Speed accuracy (open loop) <1.1 kW
Speed accuracy (open loop) >0.75 kW
Speed accuracy (closed loop)
All control characteristics are based on a 4-pole asynchronous motor
Surroundings:
Enclosure
Enclosure T73 version
Vibration test
Max. relative humidity
Ambient temperature (FCD 335 max. 35 °C)
Derating for ambient temperature, see special conditions in the Design Guide
Min. ambient temperature during full-scale operation
Min. ambient temperature at reduced performance
Temperature during storage/transport
Max. altitude above sea level
Derating for air pressure, see special conditions in the Design Guide
EMC standards used, Emission
EMC standards used, immunity
See section on special conditions in the Design Guide
Safeguards:
Electronic thermal motor protection against overload.
Temperature monitoring of the power module ensures that the frequency converter cuts out if the temperature reaches 100 °C. An overload
temperature cannot be reset until the temperature of the power module is below 70 °C.
The frequency converter is protected against short-circuits on motor terminals U, V, W.
If a mains phase is missing, the frequency converter will cut out.
Monitoring of the intermediate circuit voltage ensures that the frequency converter cuts out if the intermediate circuit voltage is too low or too
high.
The frequency converter is protected against earth fault on motor terminals U, V, W.
(terminals 18, 19)
EN 61000-6-2, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6
MG.04.B8.02 - VLT is a registered Danfoss trademark
0.2 - 132 Hz, 1 - 1000 Hz
1:15 of synchronous speed
approximately 1:10 of synchronous speed (motor dependent)
1:120 of synchronous speed
150 - 3600 rpm: Max. error of ±23 rpm
90 - 3600 rpm: Max. error of ±23 rpm
30 - 3600 rpm: Max. error of ±7.5 rpm
see Air humidity in the Design Guide
95%
Max. 40 °C (24-hour average max. 35 °C)
EN 50081-1-2, EN 61800-3, EN 55011
4 All about FCD 300
10 m
10 m
4.0 mm
2
/10 AWG
2.5 mm
2
/12 AWG
2
2.5 mm
/12 AWG
2
6.0 mm
/9 AWG
2
4 mm
/10 AWG
4 mm
2
/10 AWG
4
10 mm
2
/7 AWG
16 mm
2
/ 5 AWG
0.013 Hz, 0.2 - 1000 Hz
≤ ± 0.5 msec
≤ 26.6 msec
IP 66, TYPE 4x (indoor)
IP 65, TYPE 12
1.0 g
0 °C
- 10 °C
-25 - +65/70 °C
1000 m
97