Entering The Signal Path Parameters; Entering The Fluid Parameters - GE Transport PT878 Abridged Manual

Portable liquid ultrasonic flowmeter
Hide thumbs Also See for Transport PT878:
Table of Contents

Advertisement

August 2008
Entering the Fluid
Parameters (cont.)
Entering the Signal Path
Parameters
2-8
Table 2-2: Fluid Type Selection
Energy
Tracking Windows OFF
OFF
Other
Water (0-260°C)
Sea Water
Oil (22°C)
Crude Oil
Lube Oil (X200)
Methanol
Ethanol
LN2 (-199°C)
Freon (R-12)
ON
Water/0-260°C
Water/Glycol
(with glycol %)
Other
(single soundspeed)
To program your signal path parameters, scroll to the Path tab on the
Program Menu (see Figure 2-6 below) and press
Transducer
Path Length
Axial Length
Traverses
Spacing
Figure 2-6: The Path Option Window
Tracking Windows ON
Water (0-260°C)
Water/0-260°C
(with glycol %)
(min./max. soundspeeds)
Transducer/Pipe
Pipe
Lining
Fluid
248.92
mm
mm
203.2
1
90
mm
Cancel
Oil
Other
Water/Glycol
Other
[ENTER]
.
Path
OK
Initial Setup