Remfr Instruction - Mitsubishi MELSEC-L series Programming Manual

Hide thumbs Also See for MELSEC-L series:
Table of Contents

Advertisement

Z_REMFR
5.4.13

REMFR instruction

Z(P)_REMFR
Structured ladder
Z_REMFR
EN
ENO
Jn*
n1
n2
n3
n4
n5
Input argument
EN:
Jn*:
n1:
n2:
n3:
n4:
n5:
Output argument
ENO:
d1:
d2:
5.4 CC-Link IE Controller Network, MELSECNET/H, and Ethernet Instruction
5-190
5.4.13 REMFR instruction
ST
d1
ENO:=
(EN, Jn*, n1, n2, n3, n4, n5, d1, d2);
Z_REMFR
d2
Executing condition
Network number of the host station
Channel number
Target station number
Start I/O number of the target intelligent function module
Specifies the higher three digits when expressing the I/O
number for the intelligent function module mounted to the
target remote I/O station in four digits.
Read buffer memory start address
Specifies the start address of the buffer memory for the read
destination intelligent function module.
Number of read points (in units of words)
Execution result
Start number of the device that stores read data (host station)
Specifies the start number of the host station's device that
stores read data.
Variable that turns ON upon completion of the instruction
d2[1] also turns ON at the time of error completion.
Setting
Internal device
*1
data
Bit
Word
n1
n2
n3
n4
n5
d1
d2
P: Executing condition
instructions.
Z_REMFR
:Bit
:String
:ANY16
:ANY16
:ANY16
:ANY16
:ANY16
:Bit
:ANY16
:Array of bit [0..1]
J
\
R, ZR
Bit
Word
*1: Local devices and file registers per program cannot be used as setting data.
Z_REMFR
NET/H
:
indicates any of the following
ZP_REMFR
Constant
Zn
U
\G
K, H
Others

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec-q series

Table of Contents