Shrouds
A. HHT Shrouds
•
You may install a shroud with this fi replace. See Section 17.D. for a list of UL Listed shrouds. Follow the instructions
included with these optional components
B. Field Constructed Shrouds
WARNING! Risk of Fire!
as specifi ed. Improper construction may overheat chase
top.
•
Chase top shrouds may be fi eld constructed where permitted by regional building codes.
NOTICE:
Some regional codes require an agency-Listed
shroud. Consult your local building offi cials.
•
The following fi eld constructed shroud designs have been tested for Hearth Technologies fi replace systems and termination
caps.
•
The shrouds must be constructed from a minimum .018 in. (26 ga) thick aluminized steel.
•
The wire mesh is optional but recommended and must be .018 in. thick minimum, 1/2 in. mesh.
Open Top Shroud (may be used with DVP-TV, DVP-TVHW, SLP-TVHW)
Min.
Top Dim.
Min.
Top Dim.
Min.
Base Dim.
Figure 11.1 Open Top Shroud Dimensions
48
Shrouds must be constructed
Min.
Base Dim.
Quadra-Fire • QFP38 Series • 4061-300 Rev i • 9/09
Min. Base Dims.
in
19 x 19
mm
483 x 483
Min. Top Dims.
in
16 x 16
mm
406 x 406