Mantel And Wall Projections - Quadra-Fire QFP38-LP Owner's Manual

Installation and operation
Table of Contents

Advertisement

D. Mantel and Wall Projections
WARNING! Risk of Fire!
ances to combustibles as specifi ed. Framing or fi nishing
material closer than the minimums listed must be construct-
ed entirely of non-combustible materials (i.e., steel studs,
concrete board, etc).
Mantels
0 - 10
22
Measured from appliance opening (in inches)
Figure 5.3
Clearances to Mantels or Other Combustibles above
Appliance
30
Comply with all minimum clear-
30 in. minimum
to ceiling
12
11
23
22 1/2
Quadra-Fire • QFP38 Series • 4061-300 Rev i • 9/09
Mantel Legs or Wall Projections
Top of
Appliance
A
5 in. (127 mm) Min.
to perpendicular wall
B
6 in. (152 mm) Min.
from fireplace opening
to perpendicular wall
Figure 5.4
Mantel Leg or Wall Projections (Acceptable on both
sides of opening)
Drywall
A
B
Mantel Leg or
Perpendicular Wall