This installation guide provides basic guidelines for the Rosemount 3051S ERS System (reference
manual document number 00809-0100-4804). It does not provide instructions for diagnostics,
maintenance, service, or troubleshooting. This document is also available electronically on
www.rosemount.com.
Explosions could result in death or serious injury:
Installation of this transmitter in an explosive environment must be in accordance with the appropriate
local, national, and international standards, codes, and practices. Please review the approvals
section of the 3051S ERS System reference manual for any restrictions associated with a safe
installation.
• Before connecting a Field Communicator in an explosive atmosphere, ensure the instruments in
the loop are installed in accordance with intrinsically safe or non-incendive field wiring practices.
• In an Explosion-proof/Flameproof installation, do not remove the transmitter covers when power
is applied to the unit.
Process leaks may cause harm or result in death.
• Install and tighten process connectors before applying pressure.
Electrical shock can result in death or serious injury.
• Avoid contact with the leads and terminals. High voltage that may be present on leads can cause
electrical shock.
Conduits/Cable Entries
• Unless otherwise marked, the conduit / cable entries in the 3051S ERS housing enclosure use a
1
/
-14 NPT form. Only use plugs, adapters, glands, or conduit with a compatible thread form
2
when closing these entries.
2

IMPORTANT NOTICE

WARNING
Emerson Process Management
GmbH & Co. OHG
Argelsrieder Feld 3
82234 Wessling
Germany
T 49 (8153) 9390, F49 (8153) 939172
Beijing Rosemount Far East Instrument Co., Limited
No. 6 North Street, Hepingli, Dong Cheng District
Beijing 100013, China
T (86) (10) 6428 2233
F (86) (10) 6422 8586
Quick Installation Guide
00825-0100-4804, Rev AB
January 2011