AKD-N Installation | 5   Approvals

5.1 Conformance with UL/cUL

This drive is listed under UL (Underwriters Laboratories Inc.) file number E217428. UL Markings are combined for
both AKD-C and AKD-N in one section.

5.1.1 UL Markings / Marquages UL

English
This product is suitable for use on a circuit cap-
able of delivering not more than 42,000 rms sym-
metrical amperes, 480 V maximum.
Maximum surrounding air temperature 40°C.
AKD-C are intended to be used in a pollution
degree 2 environment.
AKD-C : Use 60/75°C copper wire only.
AKD-C : CAUTION Risk of Electrical Shock!
Capacitors can have dangerous voltages present
up to 7 minutes after switching off the supply
power. For increased safety, measure the
voltage in the DC bus link and wait until the
voltage is below 50 V.
For use in Canada:
Transient surge suppression shall be installed on
the line side of this equipment and shall be rated
277 V (phase to ground), 480 V (phase to phase),
suitable for overvoltage category III, and shall
provide protection for a rated impulse withstand
voltage peak of 2 kV.
The following fuse types are recommended for branch circuit protection for AKD-C01007-CBXX:
Les types de fusibles suivants sont recommandés pour protection de secteur pour AKD-C01007-CBXX:
Model/
Modèle
Nonrenewable Cartridge fuse
The following table illustrates the torque requirements for the field wiring connectors :
Le tableau suivant indique les spécifications de couple pour les connecteurs de câblage sur site:
Model/Modèle Torque/Couple serrage, LB IN (Nm)
AKD-C X12
6.2 - 7.1 (0.7 - 0.8)
AKD-C X20A
6.2 - 7.1 (0.7 - 0.8)
AKD-C X21A
6.2 - 7.1 (0.7 - 0.8)
AKD-C X14
6.2 - 7.1 (0.7 - 0.8)
AKD-C X13
1.8 - 2.2 (0.2 - 0.25)
AKD-C X15
1.8 - 2.2 (0.2 - 0.25)
AKD-C X16
1.8 - 2.2 (0.2 - 0.25)
Split gage of AKD-N screwed connectors: max. 2.8 mm.
Le gage de split des connecteurs vissé d'AKD-N: 2,8 mm max.
Cold plate for AKD-N: at 40°C surrounding air temperature and 680 VDC supply voltage:
Plaque froide pour AKD-N: à température ambiante 40°C et tension d'alimentation 680 VDC:
- AKD-N00307: 240 mm x 240 mm x 10 mm or equivalent (LxWxT, Aluminum cold plate, uncoated)
- AKD-N00607: 500 mm x 500 mm x 10 mm or equivalent (LxWxT, Aluminum cold plate, uncoated)
- AKD-N01207: 480 mm x 400 mm x 84 mm or equivalent (LxWxT, 31 vertical fins, Aluminum heat sink,
uncoated)
20
Kollmorgen | kdn.kollmorgen.com | February 2018
Français
Ce produit est conçu pour une utilisation sur un circuit
capable de fournir 42.000 ampères symétriques (rms)
maximum pour 480 V maximum.
La température maximale de l'air ambiant de 40°C.
AKD-C sont prévus pour une utilisation dans un
environnement de pollution de niveau 2.
AKD-C: Utilisez seulement un fil cuivre 60/75°C.
AKD-C : ATTENTION: Risque de choc électrique!
Des tensions dangereuses peuvent persister dans les
condensateurs jusqu'à 7 minutes après la mise hors
tension. Pour plus de sécurité, mesurez la tension
dans la liaison de bus CC et attendez qu'elle soit
inférieure à 50 V.
Pour utilisation au Canada:
Suppression de surtension transitoire doit être installé
sur le côté de la ligne de ce matériel et doit être évalué
277 V (phase à terre) , 480 V (entre phases) , adapté à
la catégorie de surtension III , et doit fournir une pro-
tection pour un choc nominale supporter la tension de
crête de 2 kV.
Class/
Voltage Rating/
Classe
Niveau de tension
CC, J
600 VAC
Max. Fuse&SCC Rating/
Niveau maximum & SCC
20 A, 200 kA
Wire size/Section de fil, AWG (mm²)
12 - 8 (4 - 10)
12 - 8 (4 - 10)
12 - 8 (4 - 10)
12 - 8 (4 - 10)
14 - 12 (2.5 - 4)
20 - 18 (0.5 - 0.8)
20 - 18 (0.5 - 0.8)