Print Menu; Settings Menu - Felix printers Tec 4 User Manual

Hide thumbs Also See for Tec 4:
Table of Contents

Advertisement

Display functions

Print Menu

Back ←
Folder 1
Printfile.gcode

Settings menu

Back ←
Info
Tot. Time: ...H
Tot. Filament.: ...m
Language
English
Deutsch
Espanol
...
ONLY CHANGE BELOW SETTINGS IF YOU KNOW WHAT YOU ARE DOING
Extruder
Select Extr. 1
Select Extr. 2
X-Offset: 0.00
Y-Offset: 0.00
Steps/MM: 147
Start FR: 5
Max FR: 30
Accel: 10000
Stab.time: 1
Wait Retr.: 0mm
Wait Temp. 150C
Advance Lin: 0
Advance quad: 0
Control: PID
PID P: 20.00
PID I: 0.60
PID D: 65.00
Drive Min: 40
Drive Max:220
PID Max::255
Build Platform
Build PLT Coating
BuildTak
Kapton
Custom: 0.10mm
Control: PID
PID P: 100.00
PID I: 0.50
PID D: 150.00
Drive Min: 0
Drive Max: 255
PID Max:255
Baudrate:115200
Save Settings
FELIX Tec 4
Return to previous menu.
Folder
Printfile. Only *.gcode files can be printed.
Return to previous menu.
General info
Total printed time in hours
Total extruded filament in meters.
Choose your language
Extruder settings
Currently active extruder (see white square in front)
X-offset of extruder (this is only used for extruder 2)
Y-offset of extruder (this is only used for extruder 2)
Motor steps to extruder 1mm of filament
Start feedrate of extrusion
Maximum feedrate of extrusion
Acceleration of extrusion
Temperature stabilization time.
Filament retraction amount when printer is waiting to reach temperature
Waiting temperature during pause
Extruder linear advance parameter.
Extruder quadratic advance parameter.
Heating strategy, standard PID control
Proportional control value
Integral control value
Derivative control value
Minimum PID control value
Maximum PID control value
Maximum PID value
Build platform control
Build platform coating setting, used to add offset between nozzle and bed after
homing.
Heating strategy, standard PID control
Proportional control value
Integral control value
Derivative control value
Minimum PID control value
Maximum PID control value
Maximum PID value
Set communication baudrate between printer, must reboot printer to activate.
Save changed settings.
User Manual
18 December 2017
www.FELIXprinters.com
10

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents