Evacuating Condensate Water During An Emergency; Wall Split Installation Procedures; Instructions For Installation - Olimpia splendid Unico Twin Instructions For Installation, Use And Maintenance Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 37
2
Should the conditioner block and signal an error (as indicated in the following table), specify the LEDs that are flashing to the
service centre in order to facilitate the intervention (fig. 24).
DESCRIPTION
UNICO unit internal exchanger overtemperature (HTI)
UNICO unit external exchanger overtemperature (HTE)
UNICO unit outdoor temp. probe fault (short circuit) (TFS7)
UNICO unit outdoor temperature probe fault (open circuit) (TFS8)
UNICO unit internal fan malfunction (SV)
UNICO unit insufficient exchanger temperature (CF/RL)
UNICO unit condensation water maximum level (OF)
UNICO unit EEprom parameters not valid (CKS)
UNICO unit ambient temperature probe fault (short circuit) (TFS1)
UNICO unit ambient temperature probe fault (open circuit) (TFS2)
UNICO unit internal exchanger temperature probe fault
(short circuit) (TFS3)
UNICO unit internal exchanger temperature probe fault
(open circuit) (TFS4)
UNICO unit external exchanger temperature probe fault
(short circuit) (TFS5)
UNICO unit external exchanger temp. probe fault (open circuit)
(TFS6)
SPLIT unit malfunction
: flashing
WARNINGS SIGNALLED DURING NORMAL OPERATION SHOULD NOT BE INTERPRETED AS ANOMALIES.
LED A: indicates the filter may need cleaning
After this operation the LED must be switched off manually as indicated in section 2.4.1
LED B steady light: high battery temperature signal.
LED A + LED C flashing: continuous pump operation.
If the SPLIT unit malfunctions, the UNICO can be run temporarily on its own. To clear the alarm status and enable the UNICO unit
on its own, proceed as follows: cut the mains voltage to both units, wait a few seconds, and then reconnect the power line to the
UNICO unit only.
Once the SPLIT is working correctly again, simply power it again and it will be detected by UNICO.
2.1.13

Evacuating condensate water during an emergency

If there should be a malfunction in the condensation water drain system, the air conditioner stops working and signals, with flashing
orange, green and red lights (the second and third LEDs from the left), the alarm status.
To enable the air conditioner to work temporarily until the service personnel arrive, you can drain the water out by following these
simple instructions:
-
remove the lower cover (fig. 25 ref. A)
-
remove the cap (fig. 25 ref. B) after having placed a good-sized container underneath it (at least 5-liter capacity) to collect the
water (see fig. 25)
-
after having cleared the fault, the service personnel will close the evacuation pipe.
2.2

WALL SPLIT INSTALLATION PROCEDURES

2.2.1

Instructions for installation

To obtain the best results and optimum performance, follow the instructions for correct installation provided in this manual.
Failure to follow the instructions and apply the rules indicated may cause malfunction of the appliance and relieves the manufacturer,
OLIMPIA SPLENDID of any form of guarantee and liability for damages to persons, animals or property.
The electrical system must comply with the regulations and rating data in the technical sheet, with good grounding.
LED D
LED C
LED B
GREEN
YELLOW
GREEN
OFF
OFF
ON
OFF
OFF
ON
OFF
ON
OFF
OFF
OFF
ON
OFF
ON
ON
OFF
ON
ON
OFF
ON
OFF
ON
ON
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
ON
LED A
RED
OFF
ON
OFF
OFF
OFF
ON
OFF
ON
OFF
ON
OFF
OFF
OFF
ON
OFF
OFF
OFF
ON
OFF
ON
OFF
ON
45
UNICO TWIN
2

Advertisement

Table of Contents
loading

Table of Contents