Type
No.
Fault
Unstable
combustion
ALL
89
feedback signal
error
Combustion set
ALL
90
cannot be reached
error
System has
reached maximum
ALL
92
air correction error
(at the minimum
flow rate)
Combustion set
ALL
93
cannot be reached
error
Flame
ALL
95
signal micro
interruptions error
Block due to
ALL
96
clogging in smoke
outlet
SW error, board
ALL
98
start-up
General board
ALL
99
error
Frequent relief
-
-
valve intervention
Limited production
-
-
of domestic hot
water
64
Solution
- Check electrode
- Check outlets
- Check air diaphragm (for BF
models)
- Check gas calibration
- Check electrode
- Check outlets
- Check air diaphragm (for BF
models)
- Check gas calibration
- Check electrode
- Check outlets
- Check air diaphragm (for BF
models)
- Check gas calibration
- Check electrode
- Check outlets
- Check air diaphragm (for BF
models)
- Check gas calibration
- Check electrode
- Check board
- Check electric power supply
- Check gas calibration
- Check for blockage in chimney
- Check the smoke outlet and
electrode position (not touching
the burner)
- Contact the Technical
Assistance Centre
- Contact the Technical
Assistance Centre
- Check circuit pressure
- Check expansion vessel
- Check the diverter valve
- Check that plate heat
exchanger is clean
- Check domestic hot water
circuit valve
Heat pump fault
Type
No.
Description
P
02
High pressure
P
04
Low pressure
Antifreeze (heat
P
12
exchanger temp. < 3°C)
High temperature (HP
P
15
delivery temp. > 50°C)
Probe errors aggregate
P
32
(one or more probes with
an active alarm)
Battery temperature
P
33
probe error
Inlet water temperature
P
34
probe error
Outlet water temperature
P
35
probe error
Solution
Automatic reset
Remove and reconnect
the electrical power
supply
Automatic reset
Remove and reconnect
the electrical power
supply
Wait for heat exchanger
temp. > 5°C
Automatic restore when
delivery temp. < 48°C
Automatic restore after
sensor replaced
Replace the damaged
probe
Replace the damaged
probe
Replace the damaged
probe
Need help?
Do you have a question about the MURELLE REVOLUTION 25 and is the answer not in the manual?
Questions and answers