– Turn the
encoder to modify the first digit from 0 to 1
– Press the
encoder to confirm the modification and
click
select the next digit
– Continue in this way until the CODE (or password) "1 2 3 4 5"
has been completed
Code:
Cancel
– Press the
Confirm
area
settings"
Parameter Index: 1
Parameter Value: 0
Esc
– The "Parameter index" refers to the parameter table below
– Turn the
encoder to scroll through the list of
parameters and check the value.
Type
No.
Description
Index showing boiler power in kW
PAR
01
5 = 25 (Murelle Revolution 25)
6 = 30 (Murelle Revolution 25 30)
Hydraulic configuration
0 = rapid
1 = storage tank with thermostat or heating only
PAR
02
2 = hot water tank with sensor
3 = bithermic
4=instant with solar power input
Gas Type Configuration
PAR
03
0 = G20; 1 = G31
Combustion configuration
PAR
04
0 = sealed chamber with combustion control
PAR
08
External sensor value correction
PAR
09
Ignition fan speed
PAR
10
Boiler Antifreeze Threshold
External Sensor Antifreeze Threshold
PAR
11
-- = Disabled
PAR
12
Heating Curve Incline
PAR
13
Minimum Heating Temperature Adjustment
PAR
14
Maximum Heating Temperature Adjustment
PAR
15
Maximum power heating
PAR
16
Heating Post-Circulation Time
PAR
17
Heating Pump Activation Delay
PAR
18
Re-ignition Delay
54
ENTER ACCESS CODE
1 2 3 4 5
Confirm
button to access the boiler "Parameter
Boiler parameters
1--------49
Back
DOMESTIC HOT WATER - HEATING
If the value of the selected parameter is to be modified:
– Press the
area
Fig. 148
– Press the
– Press the
move on to another parameter
– Once all the display/modification commands have been
completed, press the
"Main screen"
Fig. 149
CONFIGURATION
20 .. PAR 14
PAR 13 .. 80
click
encoder to access the value modification
Boiler parameters
1--------49
Parameter Index: 1
Parameter Value: 0
Esc
Back
encoder to set the new value
click
encoder to confirm the modification and
button to go back to the
Esc
.
Zone
Thu 18 Set 2014
Off
Menu
Mode
Range
U/M
0 .. 6
-
0 .. 4
-
0 .. 2
-
-
-
-5 .. +5
°C
80 .. 160
RPMx25
0 .. +10
°C
-9 .. +5
°C
0 .. 80
-
°C
°C
0 .. 100
%
seconds
0 .. 99
x 10
seconds
0 .. 60
x 10
0 .. 60
Min
Fig. 150
10:30
Fig. 151
Step
Default
1
5
1
0
1
0
-
0
1
0
1
128
1
3
1
-2
1
20
1
20
1
65
1
100
1
3
1
0
1
3