Download Print this page

Axminster AWSS-18 Flex User Manual page 12

Scroll saw

Advertisement

Align the bevel indicator (Fig. 3-5)
The bevel indicator has been factory adjusted. It should be
rechecked prior to use best operation.
1. Remove the blade guard foot (1)
using a hex key to loosen the
screw (2).
2.
Loosen the table bevel lock handle
(3) and turn the table adjustment
knob (4) to move the table until it
is approximately at a right angle to
the blade.
3.
Use a combination square (5) (not
provided) to set the table exactly
90º to the blade (6). If there is
space between the square and
blade, adjust the table angle until
the space is closed.
4.
Tighten the table bevel lock handle
(3) to prevent movement.
5.
Loosen the screw (7) holding the
bevel scale pointer and position
pointer to 0º. Tighten the screw.
6.
Attach the blade guard foot (1) and
tighten the screw (2),
WARNING:
• When carrying the saw, hold it close to your body to avoid injury
to your back. Bend your knees when lifting the saw.
• Carry the saw by the base. Do not carry the saw by the power
cord.
• Secure the saw in a position where people cannot stand, sit, or
walk behind it. Debris thrown from the saw could injure people
standing, sitting, or walking behind it.
• Secure the saw on a firm, level surface where the saw cannot
rock and there is adequate room for handling and properly
supporting the workpiece.
To reduce the risk of injury:
2
Fig. 4
7
4
Fig. 5
5
6
Fig. 3
1
3

Advertisement