How To Set The Notification - Furuno FA-170 Operator's Manual

Class a ais u-ais transponder
Hide thumbs Also See for FA-170:
Table of Contents

Advertisement

1. OPERATION
1.7

How to Set the Notification

The [NOTIFICATION SET] menu is used to set the following items:
• Enable or disable the alert buzzer.
• Notifications for received [ADDRESSED] and [BROADCAST] messages.
• Notifications for collision detection.
To change the settings in the [NOTIFICATION SET] menu, do the following:
1. Press the MENU/ESC key to open the main menu.
2. Select [USER SET], then press
the ENT/ACK key.
3. Select [NOTIFICATION SET],
then press the ENT/ACK key.
The [NOTIFICATION SET]
screen appears.
4. Select the [BUZZER] item be-
low [ALERT], then press the
ENT/ACK key. The settings
pop up window appears.
5. Select [ON] to enable the alert buzzer, or select [OFF] to disable the alert buzzer,
then press the ENT/ACK to confirm the setting.
6. Select the [ADDRESSED] item below [RX MESSAGE], then press the ENT/ACK
key. The settings pop up window appears.
7. Select the appropriate setting, referring to the table below, then press the ENT/
ACK key.
POPUP + BUZZER
POPUP
OFF
8. Set the notifications for [BROADCAST] RX messages and [COLLISION DETECT]
in the same manner.
9. Select the [CPA THREHOLD] item in [COLLISION DETECT], then press the ENT/
ACK key to show the setting window for [CPA THREHOLD] is as shown.
10. Press
are 0.0 NM to 6.0 NM.
11. Select the [TCPA THREHOLD] item in [COLLISION DETECT], then press the
ENT/ACK key to show the setting window for [TCPA THREHOLD] is as shown.
Note: When both CPA and TCPA are below the [CPA THREHOLD] and [TCPA
THREHOLD] setting values, the collision alarms is available.
12. Press
min to 60 min.
13. Press the DISP key to close the menu.
1-10
Setting
Enable both the pop up indication and the buzzer.
Enable only the pop up indication. (No buzzer.)
Disable notifications.
or
to set a range, then press the ENT/ACK key. The available ranges
or
to set a time, then press the ENT/ACK key. The available time is 0
NOTIFICATION SET
[ALERT]
BUZZER
:
ON
[RX MESSAGE]
ADDRESSED
:
POPUP
BROADCAST
:
POPUP + BUZZER
[COLLISION DETECT]
INDICATION
:
POPUP
CPA THRESHOLD
:
6.0NM
TCPA THRESHOLD
:
60min
: CURSOR
: SELECT
ENT
Description
: BACK
ENT

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents