Chapter 5
8C83: Error in memory subsystem: Upper Board, DIMM 19
8C84: Error in memory subsystem: Upper Board, DIMM 20
8C85: Error in memory subsystem: Upper Board, DIMM 21
8C86: Error in memory subsystem: Upper Board, DIMM 22
8C87: Error in memory subsystem: Upper Board, DIMM 23
8C88: Error in memory subsystem: Upper Board, DIMM 24
8C89: Error in memory subsystem: Upper Board, DIMM 25
8C8A: Error in memory subsystem: Upper Board, DIMM 26
8C8B: Error in memory subsystem: Upper Board, DIMM 27
8C8C: Error in memory subsystem: Upper Board, DIMM 28
8C8D: Error in memory subsystem: Upper Board, DIMM 29
8C8E: Error in memory subsystem: Upper Board, DIMM 30
8C8F: Error in memory subsystem: Upper Board, DIMM 31
8C90: Error in memory subsystem: Upper Board, DIMM 32
8C91: DIMMs mapped out: Lower Board, 1 - 4
8C92: DIMMs mapped out: Lower Board, 9 - 12
8C93: DIMMs mapped out: Lower Board, 17 - 20
8C94: DIMMs mapped out: Lower Board, 25 - 28
8C95: DIMMs mapped out: Lower Board, 5 - 8
8C96: DIMMs mapped out: Lower Board, 13 - 16
8C97: DIMMs mapped out: Lower Board, 21 - 24
8C98: DIMMs mapped out: Lower Board, 29 - 32
8C99: DIMMs mapped out: Upper Board, 1 - 4
8C9A: DIMMs mapped out: Upper Board, 9 - 12
8C9B: DIMMs mapped out: Upper Board, 17 - 20
8C9C: DIMMs mapped out: Upper Board, 25 - 28
8C9D: DIMMs mapped out: Upper Board, 5 - 8
8C9E: DIMMs mapped out: Upper Board, 13 - 16
8C9F: DIMMs mapped out: Upper Board, 21 - 24
8CA0: DIMMs mapped out: Upper Board, 29 – 32
5

Troubleshooting

Preventive Maintenance Procedures

Refer to this table for preventive maintenance procedures for this HP Server. Be sure to turn off power to the
HP Server when cleaning it.