10. Accessory During Diesel Start Delay
1. ON: the Accessory outputs (Orange wire 10-pin harness (high current) and (-) Accessory Orange
wire 24-pin harness (low current)) will be ON during diesel start delay.
2. OFF: the Accessory outputs (Orange wire 10-pin harness (high current) and (-) Accessory Orange
wire 24-pin harness (low current)) will be OFF during diesel start delay.
11. Status 2 Output (Blue/White wire on 24-pin harness)
1. Status: the output will activate before the ignition outputs turns ON, and de-activates after they turn
OFF during remote start.
2. Latch rear defogger: the output activates 10 seconds after start if the temperature at the remote start
main unit is below 55°F. It turns OFF after 10 minutes or upon remote start OFF.
3. Pulse rear defogger: the output activates (for 800 ms) 10 seconds after start if the temperature at
the remote start main unit is below 55°F.
Note: If the rear defogger feature is programmed ON, the customer can still enable/disable the output
with the remote.
12. Parking Light Output
1. Constant: the parking lights will turn ON solid during remote start.
2. Pulsed: the parking lights will pulse ON/OFF during remote start.
3. OFF: the parking lights will be OFF during remote start.
Note: If the parking lights have been programmed to be OFF during the remote start runtime, the
parking lights will still flash upon activation of the remote start and during startup diagnostics.
13. Anti-grind Output (Orange wire on 6-pin harness)
1. ON: the Orange Ground When Armed output will be activated for an optional anti-grind relay
during remote start as anti-grind protection.
2. OFF: the Orange Ground When Armed output will not be activated during remote start, no anti-
grind protection is available.
Note: The Ground When Armed output will still activate/deactivate when the system is Locked/
Unlocked if the remote start is active.
14. Tach Mode Starter Release
1. Normal: the starter output will release normally during cranking (50% of the learned tachometer
value).
2. Increase: the starter output will release later during cranking (at 35% of the learned tachometer
value).
3. Decrease: the starter output will release sooner during cranking (at 35% of the learned tachometer
value).
15. Vehicle Temp Auto Report
1. OFF: the report during remote start is defeated.
2. ON: the report is sent every 2 minutes during remote start if the temperature has changed (+/-) 1
degree since the last report.
16. Remote Start Safelock
1. OFF: the Door lock output will maintain the current status (locked/unlocked) during remote start and
after shut down.
2. On: the Door lock output will arm/lock the vehicle after the crank output from the remote start and
once again after the remote start shuts OFF.