Auxiliary/Shutdown Harness, 24-pin connector
Important: Never connect the 200mA low current outputs directly to a motor or high current device
WITHOUT a relay.
Pink/White: (-) IGNITION 2/FLEX OUTPUT
This (-) 200mA output wire works in conjunction with the (+) Pink/White wire in the heavy gauge harness.
It comes factory set as Ignition 2 and can be programmed for an Accessory or Starter output. It is typically
used to activate a relay for an additional (+) Ignition, Accessory or Starter wire in the vehicle (see Flex Relay
Function in Feature Menus for more details).
Note: Programming this wire also affects the timing of the heavy gauge (+) Pink/White wire.
Blue/White: (-) 2ND STATUS/REAR DEFOGGER OUTPUT
This (-) 200mA output is default for status output and will activate as soon as the remote start process begins
and will stay active while the remote start is ON, it is typically used to activate a module or any accessory
which requires a ground during the remote start sequence. This wire can also be programmed to activate a
defogger circuit in the vehicle (see Status 2 Output in Feature Menus for more details).
Red/White: (-) AUX/TRUNK RELEASE OUTPUT
This (-) 200mA output is often used to operate a trunk/hatch release or other relay-driven functions. When the
system receives the command controlling trunk release (for longer than 1.5 seconds) the Red/White wire will
supply an output as long as the transmission continues. This output can also be programmed as a 2nd Unlock
output when driver's priority unlock is desired (see Aux/Trunk Output Type in Feature Menus for more details).
Black/Yellow: (-) DOME LIGHT OUTPUT
This (-) 200mA output is used to drive the dome light circuit in the vehicle. This output activates when unlocking
the system and when turning the ignition OFF (ignition controlled Dome Light is programmable ON/OFF).
(see Ign-controlled Dome Light in Feature Menus for more details).
Dark Blue: (-) STATUS OUTPUT
This (-) 200mA output will activate as soon as the remote start process begins and will stay active while the
remote start is ON, it is typically used to activate an interface module or any accessory which requires a
ground during the remote start sequence.
White/Black: (-) AUXILIARY 3 OUTPUT
This (-) 200mA output is used for controlling any auxiliary function such as fuel door release or a window
module. This output can be programmed for different applications. (see the AUX 3 Output options in Feature
Menus for more details).
White/Violet: (-) AUXILIARY 1 OUTPUT
This (-) 200mA output is used for controlling any auxiliary function such as fuel door release or a window
module. This output can be programmed for different applications. (see the AUX 1 Output options in Feature
Menus for more details).
Orange/Black: (-) AUXILIARY 4 OUTPUT
This (-) 200mA output is used for controlling any auxiliary function such as fuel door release or a window
module. This output can be programmed for different applications. (see the AUX 4 Output options in Feature
Menus for more details).
Gray: HOOD TRIGGER INPUT (N/O OR N/C)
This input wire is used to prevent the remote start from activating if the hood is open. This wire can also be
programmed for a N/O (Normally Open) or N/C (Normally Closed) circuit.
N/O = rests at ground when the hood is OPEN, N/C = rests at ground when the hood is CLOSED. (see Hood
Switch Type in Feature Menus for more details).