1. One-time Bypass
1. OFF: One-Time Bypass is not available.
2. ON: the One-Time Bypass feature will defeat Passive Locking once and, if Locked by remote control,
will defeat Comfort Closure and AUX outputs linked to Locking.
2. Override Pulse Count
1-5: sets the number of presses (1-5) on the Control Center button required to disengage the Ground
When Armed output from the system if a remote is damaged or not available.
3. Door Open Error Chirp
1. ON: if the door trigger is active when locking, the horn will emit a honk and a message will be sent
to the 2-way remote control as an alert.
2. OFF: an active door trigger when locking will not create an alert output.
4. OEM Alarm Disarm with Aux/Trunk (Green/Black wire, 24-pin harness)
1. ON: the OEM Alarm Disarm wire will pulse as programmed when the Aux/Trunk output is
activated.
2. OFF: the OEM Alarm Disarm wire will not pulse when the Aux/Trunk output is activated.
5. OEM Alarm Disarm Output (Green/Black wire, 24-pin harness)
1. With Unlock: the OEM Alarm Disarm wire will pulse as programmed at the same time as the unlock
(Blue) wire.
2. Before Unlock: the OEM Alarm Disarm wire will pulse as programmed before the unlock wire.
3. Remote start only: the OEM Alarm Disarm wire will pulse as programmed during remote start only.
6. OEM Alarm Disarm Pulses (Green/Black wire, 24 pin harness).
1. The OEM Alarm Disarm wire will pulse once per operation.
2. The OEM Alarm Disarm wire will pulse twice per operation.
7. AUX 1 Output Type (White/Violet wire, 24-pin harness)
1. Validity: when the AUX command is received the output will turn ON and remain ON until the
command ceases.
2. Latch: when the AUX command is received the output will turn ON and remain ON until the
command is received again.
3. Latch/reset/Ignition: when the AUX command is received the output will turn ON and remain ON
until the command is received again or the ignition is turned ON/OFF.
4. Timed: when the AUX command is received the output will turn ON for the programmed time
duration (default 30sec.).
5. OFF: the output will not activate for a remote control command, use this option when the AUX
command controls an external device such as a garage door module.
6. 2nd Unlock: this output will operate as 2nd Unlock and will not activate for remote control
commands.
8. AUX 1 Linking
1. No Linking: the AUX output will operate normally with the remote control.
2. Link to Lock: the AUX output will activate for the Lock command.
3. Link to Unlock: the AUX output will activate for the Unlock command.
4. Link to Lock/Unlock: the AUX output will activate for the Lock & Unlock commands.
5. Link to Remote Start: the AUX output will activate for any Remote Start activation.
Note: The auxiliary output can still be activated independently with the remote when linked to a
command.