2 TX
3 RX
5 GND
8 CTS
Serial Settings
The serial output is set at 8 data bits, 1 stop bit and no parity. The baudrate can be selected as can RS232 or
RS485 operation.
SW1 Settings
Switch positions 1 to 4 are not used.
Switch positions 5 to 7 control the baudrate for the serial interface. Whether the serial interface is RS485 or
RS232 is selected by switch position 8.
5
6
Baudrate / USB
NA
Off
Off
9600
On
Off
19200
Off
On
38400
On
On
57600
Off
Off
115200
On
Off
230400
Off
On
460800
On
On
This switch position selects whether the serial interface is RS232 or RS485.
8
232/485
RS232
Off
RS485
On
65
Mantracourt Electronics Limited T24 Technical Manual
5
1
9
6
7
Off
Off
Off
Off
On
On
On
On