Data Provider Format - Mantracourt T24-BSi Technical Manual

T24 series
Hide thumbs Also See for T24-BSi:
Table of Contents

Advertisement

Reset
Save
Wake
Sleep
Pause
Resume
StayAwake
SleepTrigger
PauseTrigger
ResumeTrigger
StayAwakeTrigger
DoSystemZeroTrigger
NOTE: All changes require a SAVE command to enable them to survive through power cycle or RESET command.

Data Provider Format

At every TXInterval a Data Provider packet is transmitted that holds 1 value in FLOAT format (See Appendix A).
Measurement Resolution
The noise free resolution is dependant on the Sample Time (SampleTime)
SampleTime (mS)
Noise Free Resolution
> 0
16 bits
> 9
17 bits
> 99
17.5 bits
> 999
17.75 bits
Power Supply
See Appendix B – Acquisition Module Power Supply
41
Mantracourt Electronics Limited T24 Technical Manual
4
8
16
32
64
128
54
Restarts the device and utilises new channel and
encryption keys if those have been changed and saved.
55
Save any changes made to parameters. Required
before power cycling or issuing a Reset command.
Requires 500mS recovery time after executing.
50
Wake the module from sleep
56
Sends the module to Sleep
57
Stops the output streaming to allow configuration
59
Streaming continues.
58
No function other than to reset SleepDelay timer
120
Enter Data Tag to watch for that will trigger sleep
mode
121
Enter Data Tag to watch for that will trigger pause
mode
123
Enter Data Tag to watch for that will trigger resume
mode
122
Enter Data Tag to watch for that will reset SleepDelay
timer.
125
Enter Data Tag to watch for that will reset SleepDelay
timer.
Ratio
1:65,000
1:130,000
1:190,000
1:250,000
Reserved
Reserved
STATUS_POWER_UP
STATUS_BATT_LOW
STATUS_DIGITAL_INPUT
STATUS_DIGITAL_OUTPUT
Command
Command
Command
Command
Command
Command
Command
UINT16
RW
UINT16
RW
UINT16
RW
UINT16
RW
UINT16
RW

Advertisement