T24-Hr [Handheld Reader Roaming] - Mantracourt T24-BSi Technical Manual

T24 series
Hide thumbs Also See for T24-BSi:
Table of Contents

Advertisement

T24-HR [Handheld Reader Roaming]

Overview
The T24-HR is a roaming handheld that can be used to view the reading supplied by an unlimited number of
acquisition modules. The acquisition Data Tags or IDs do not need to be known beforehand.
The handheld will automatically wake any device on the same channel and encryption key.
An internal list is maintained of the top n number of acquisition modules ordered by signal level and a Next key
on the handheld allows cycling through this list.
The list size (n) is variable between 2 and 20 and this enables the viewing experience to be tailored to particular
applications.
The acquisition modules are identified by their 4 character hexadecimal Data Tags and these may be set using the
T24 Toolkit.
When in communication with a particular acquisition module the LED on that module is activated. This provides
visual feedback of the selected and currently viewed module. The LED output can also appear optionally on the
digital output.
Communications
To configure the device you will use the Read and Write mechanisms described in the Data Packet Structures
section to read and write parameters and execute commands.
Parameter List
Parameter
ID
Version
Channel
EncKey
Power
Name
Model
InputValue
DisplayValue
UseCSMA
BattLevel
OffDelay
KeyTest
Timeout
55
Mantracourt Electronics Limited T24 Technical Manual
Command
Description
Number
3
Read the unique identifier ID for this device. (3 bytes)
53
Read the firmware version.
11
Radio Channel
15
The radio encryption key to operate on. Requires
power cycle or Reset to enable.
release.
12
Set or read the output power level.
( range:0 to 100 default:100 )
10
Set or read a user defined name. (11 characters)
51
Read the model number of the device.
60
The value that is being read by the device.
61
The value being displayed by the device.
Select whether to use Carrier Sense Multiple Access
18
techniques on transmission.
Value
0
1
See Unslotted CSMA/CA in Appendix A
69
The voltage measured on the battery.
62
Time period in minutes before switching off if no
button is pressed. Setting to zero disables.
( range:0 to 1440 default:5 )
64
Set or read the state of the keys. Each time the keys
are pressed the equivalent bit will be set.
Set to zero to reset. This property is used in ATE to
test the keypad.
65
Set or read the time in seconds that if exceeded
Not supported in this
Description
Disabled
The Carrier Sense Multiple Access will be
disabled.
NOT RECOMMENDED
Enabled
The Carrier Sense Multiple Access will be
enabled.
Native
Read /
Data
Write
Type
BINARY 3
R
bytes
FLOAT
R
UINT8
RW
BINARY
RW
16 Bytes
UINT8
RW
STRING
RW
11 Bytes
STRING
R
11 Bytes
FLOAT
R
FLOAT
R
UINT8
RW
FLOAT
R
UINT16
RW
UINT8
RW
UINT16
RW

Advertisement

Table of Contents
loading

Table of Contents