Appendix 2 Error Messages

Appendix 2 Error Messages
Error in communication command (100 to 199)
Code Message
102
Syntax error
103
Invalid separator
104
Data type error
108
Parameter not allowed
109
Missing parameter
111
Header separator error
112
Program mnemonic too long
113
Undefined header
114
Header suffix out of range
120
Numeric data error
123
Exponent too large
124
Too many digits
128
Numeric data not allowed
131
Invalid suffix
134
Suffix too long
138
Suffix not allowed
141
Invalid character data
144
Character data too long
148
Character data not allowed
150
String data error
151
Invalid string data
158
String data not allowed
161
Invalid block data
App-2
Communication error messages are described below.
• If servicing is required, contact your nearest YOKOGAWA dealer as listed on the back
cover of this manual.
• For error messages other than communication error messages, see the User
Manual IM704310-01E.
Action
Syntax error other than the codes given below.
There is no <DATA SEPARATOR>.
Use a comma (,) to separate data.
Invalid <DATA> type.
See pages 2-5 and 2-6 and enter data using the correct format.
There are too many <DATA> parameters.
Check the number of parameters.
A required <DATA> parameter is missing.
Enter the required parameters.
There is no <HEADER SEPARATOR>.
Use a space to separate the header and data.
<mnemonic> is too long.
Check the mnemonic (string made of alphanumeric characters).
No such command.
Check the header.
The <HEADER> value is not correct.
Check the header.
The mantissa is missing from the value.
A mantissa must be placed before the exponent in <NRf> format.
The exponent is too large
Use a smaller number for the exponent following
Too many significant digits.
Limit the number of digits to 255 or less.
Numerical data cannot be used.
Enter the value using a format other than <NRf> format.
Invalid unit.
Check the units for <Voltage> and <Time>
The unit is too long.
Check the units for <Voltage> and <Time>
Units cannot be used.
Units cannot be used for values other than <Voltage> and <Time>.
No such selection.
Enter one of the string from {...|...|...}.
The <CHARACTER DATA> is too long.
Check the spelling of {...|...|...}.
<CHARACTER DATA> cannot be used.
Enter the value in a format other than {...|...|...}.
The right separator for <STRING DATA> is missing.
Use
"
"
"
or
"
The contents of <STRING DATA> are invalid.
The <STRING DATA> is too long or contains invalid characters.
<STRING DATA> cannot be used.
Use a data format other than <STRING DATA>.
The length of <BLOCK DATA> is not correct.
<BLOCK DATA> cannot be used.
'
"
to enclose the <STRING DATA>.
'
s
Reference Page
Chap. 2, 3
2-1
2-5 to 2-6
2-5, Chap. 3
2-5, Chap. 3
2-2
Chap. 3
Chap. 3
Chap. 3
2-5
2-5, Chap. 3
E
in <NR3> format.
"
"
2-5, Chap. 3
2-5, Chap. 3
2-5
2-5
2-5
Chap. 3
Chap. 3
Chap. 3
2-6
Chap. 3
Chap. 3
2-6, Chap. 3
IM 704310-12E