Second Parameter Specification Codes - Mitsubishi FX3U-USB-BD User Manual

Melsec-f fx series programmable controllers
Hide thumbs Also See for FX3U-USB-BD:
Table of Contents

Advertisement

FX Series PLC User's Manual - Data Communication Edition
Inverter Communication
7.7

Second Parameter Specification Codes

When handling the following parameters in computer link operation, it is necessary to select second
parameters.
In EXTR K12 and EXTR K13 instructions, when a value shown in the tables below is set to
extension parameter and second parameter are automatically overwritten, and the parameter values are then
read or written.
7.7.1
S500 Series
1. Second parameter specification codes for parameter numbers C2 to C7
Parameter
No.
C2
Frequency setting voltage bias frequency
C3
Frequency setting voltage bias
C4
Frequency setting voltage gain
C5
Frequency setting current bias frequency
C6
Frequency setting current bias
C7
Frequency setting current gain
7.7.2
E500 Series
1. Second parameter specification codes for parameter numbers 902 to 905
Parameter
No.
902
Frequency setting voltage bias
903
Frequency setting voltage gain
904
Frequency setting current bias
905
Frequency setting current gain
E-72
Name
Name
7 Creating Programs (for FX2N and FX2NC PLCs)
7.7 Second Parameter Specification Codes
Second parameter specification code
[Value to be specified in
parameter No. (decimal)]
1902
1904
Second parameter specification code
[Value to be specified in
parameter No. (decimal)]
Offset/Gain
Analog
(H00)
(H01)
902
1902
903
1903
904
1904
905
1905
S
2
in EXTR instruction for
S
2
902
903
904
905
in EXTR instruction for
S
2
Terminal analog
value (H02)
2902
2903
2904
2905
, the

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents