INSTALLATION NOTES AND USAGE

3.1 General specification

Item
General specifications(excluding withstand voltage)

3.2 Power supply specification

Item
Analog circuits
Digital circuits

3.3 Performance specifications

Analog inputs
Item
Either voltage or current input can be selected with your choice of input terminal.
Up to four input points can be used at one time.
DC -10V to +10V (input resistance:200K Ω ).
Warning:this unit may be damaged by input
Analog input range
voltage in excess of +/-15V.
12-bit conversion stored in 16-bit 2's complement form.
Digital output
Maximum value:+2047 Minimum value:-2048
Resolution
5mV (10V default range 1/2000)
Overall accuracy
+/-1% (for the range of -10V to +10V)
Conversion speed
15ms/channel (Normal speed), 6ms/channel (High speed)
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Same as those for the FX base unit
24V DC +/- 10%, 50mA(External power supply from base unit)
5V DC, 30mA(Internal power supply from base unit)
Voltage input
DC -20mA to +20mA (input resistance:250 Ω ).
Warning:this unit may be damaged by input
currents in excess of +/-32mA.
20 µ A(20mA default range 1/1000)
+/-1% (for the range of -20mA to +20mA)