Mitsubishi FX3U-USB-BD User Manual page 468

Melsec-f fx series programmable controllers
Hide thumbs Also See for FX3U-USB-BD:
Table of Contents

Advertisement

FX Series PLC User's Manual - Data Communication Edition
Inverter Communication
FREQROL F700 Series
Pr
Function
No.
RUN terminal function
190
selection
SU terminal function
191
selection
IPF terminal function
192
selection
Output terminal
OL terminal function
function
193
selection
assignment
FU terminal function
194
selection
ABC1 terminal function
195
selection
ABC2 terminal function
196
selection
Multi−speed setting
232
(speed 8)
Multi−speed setting
233
(speed 9)
Multi−speed setting
234
(speed 10)
Multi−speed
setting
Multi−speed setting
235
(speed 11)
Multi−speed setting
236
(speed 12)
Multi−speed setting
237
(speed 13)
Multi−speed setting
238
(speed 14)
Multi−speed
setting
Multi−speed setting
239
(speed 15)
Soft−PWM operation
240
selection
Analog input display
241
unit switchover
Terminal 1 added
242
compensation amount
(terminal 2)
Terminal 1 added
243
compensation amount
(terminal 4)
Cooling fan operation
244
selection
245 Rated slip
Slip compensation time
246
Slip
constant
compensation
Constant-power region
247
slip compensation
selection
-
250 Stop selection
Output phase failure
251
protection selection
Frequency
252 Override bias
compensation
253 Override gain
function
E-154
FREQROL A700 Series
Pr
Name
No.
RUN terminal function
190
selection
SU terminal function
191
selection
IPF terminal function
192
selection
OL terminal function
193
selection
FU terminal function
194
selection
ABC1 terminal function
195
selection
ABC2 terminal function
196
selection
Multi-speed setting
232
(speed 8)
Multi-speed setting
233
(speed 9)
Multi-speed setting
234
(speed 10)
Multi-speed setting
235
(speed 11)
Multi-speed setting
236
(speed 12)
Multi-speed setting
237
(speed 13)
Multi-speed setting
238
(speed 14)
Multi-speed setting
239
(speed 15)
Soft-PWM operation
240
selection
Analog input display
241
unit switchover
Terminal 1 added
242
compensation amount
(terminal 2)
Terminal 1 added
243
compensation amount
(terminal 4)
Cooling fan operation
244
selection
245 Rated slip
Slip compensation time
246
constant
Constant-power region
247
slip compensation
selection
-
250 Stop selection
Output phase failure
251
protection selection
252 Override bias
253 Override gain
FREQROL E700 Series
Pr
Name
No.
RUN terminal function
190
selection
FU terminal function
191
selection
A,B,C terminal function
192
selection
Multi-speed setting
232
(speed 8)
Multi-speed setting
233
(speed 9)
Multi-speed setting
234
(speed 10)
Multi-speed setting
235
(speed 11)
Multi-speed setting
236
(speed 12)
Multi-speed setting
237
(speed 13)
Multi-speed setting
238
(speed 14)
Multi-speed setting
239
(speed 15)
Soft-PWM operation
240
selection
Analog input display
241
unit switchover
Cooling fan operation
244
selection
245 Rated slip
Slip compensation time
246
constant
Constant-power region
247
slip compensation
selection
Earth (ground) fault
249
detection at start
250 Stop selection
Output phase loss
251
protection selection
12.5 FREQROL Inverter Parameter List
FREQROL D700 Series
Pr
Name
No.
RUN terminal function
190
selection
A,B,C terminal function
192
selection
Multi-speed setting
232
(speed 8)
Multi-speed setting
233
(speed 9)
Multi-speed setting
234
(speed 10)
Multi-speed setting
235
(speed 11)
Multi-speed setting
236
(speed 12)
Multi-speed setting
237
(speed 13)
Multi-speed setting
238
(speed 14)
Multi-speed setting
239
(speed 15)
Soft-PWM operation
240
selection
Analog input display
241
unit switchover
Cooling fan operation
244
selection
245 Rated slip
Slip compensation time
246
constant
Constant-power range
247
slip compensation
selection
Earth (ground) fault
249
detection at start
250 Stop selection
Output phase loss
251
protection selection
12 Related Data