Chapter 15 — AM/FM/PM Commands
[:SENSe]:OBWidth:METHod XDB|PERCent
[:SENSe]:OBWidth:METHod?
Description: Sets the method for calculating occupied bandwidth. XDB calculates the
Parameter: XDB|PERCent
Parameter Type: <char>
Default Value: PERCent
Related Command: [:SENSe]:OBWidth:XDB [:SENSe]:OBWidth:PERCent
Front Panel
Access: Shift-4 (Measure), RF Spectrum, Occ BW Method
[:SENSe]:OBWidth:PERCent <percentage>
[:SENSe]:OBWidth:PERCent?
Description: This command sets the percentage of carrier power used to measure the
Parameter: <percentage>
Default Value: 99
Default Unit: %
Range: 0% to 100%
Related Command: [:SENSe]:OBWidth:METHod
Front Panel
Access: Shift-4 (Measure), RF Spectrum, %
MS2720T PM
Title: Occupied Bandwidth Measurement Method
occupied bandwidth based on points a specified number of dB below the
carrier. Issue command [:SENSe]:OBWidth:XDB to set the number
of dB to be used. PERCent calculates the occupied bandwidth based on
points a specified percentage of the carrier power below the carrier.
Issue command [:SENSe]:OBWidth:PERCent to set the percentage to be
used.
Title: Occupied Bandwidth Percent of Power
occupied bandwidth. This value is used in the measurement if
:SENSe:OBWidth:METHod is set to PERCent.