KEB Combivert F5 Instruction Manual page 17

Encoder interface, channel 1 htl input without inverse signals, channel 2 htl output
Hide thumbs Also See for Combivert F5:
Table of Contents

Advertisement

Available languages

Available languages

Encoder interface HTL input / HTL output
3.1.1
Adjustment of the Supply Voltage
Figure 2.1.1 Adjustment of the supply voltage for channel 1
3.2
Channel 1
Terminal strip
Interface type
Input signals
Inputs / tracks
Output
Particularities
Limiting frequency
Increments per revolution
Input resistance
X3A
Incremental Encoder Input
HTL 15...30 V without inverse signals
A+, B+, N+
Voltage output for encoder supply
Encoder breakage recognition for all signals
100 kHz
1...16383 inc (recommendation 2500 inc for speed upto
2400 rpm
3,6 kΩ at 24 V input voltage
DIL switch S400
24 V internal or
external supply
15 V
GB-7

Advertisement

Table of Contents
loading

This manual is also suitable for:

F5

Table of Contents