9.6 General commands
You can use the following commands via the PC interface:
Command
help
tempshow
temptrace
debug
Parameter
Definition
Lists all commands
[0..254]
The measured temperature is displayed continually
at second intervals specified by the parameter:
tempshow 5<enter>
displays the current temperature every 5 seconds.
tempshow 0<enter>
switches off temperature display.
tempshow<enter>
displays the current temperature once.
The display format is as follows:
phase, seconds, +xxx, unit
Example:
Off, 31, +058, C or
Off, 31, +136, F
The data elements are separated with a comma.
If you store the data sets in your terminal program,
they can then be entered easily as .csv (comma-
separated values) into table processing programs
such as Open Office.
If the command has no parameters, the current
temperature is only displayed once.
[0..254]
The measured temperature is displayed at second
intervals specified by the parameter but only du-
ring a soldering process. Otherwise this command
is the same as "tempshow".
[0..1]
Display internal debug information
debug 1<enter>
Switch on debug information
debug 0<enter>
The form and content of status messages may
change in the case of program updates.