Advertisement

Quick Links

INSTALLER: Leave this manual with party responsible for use and operation.
OWNER: Retain this manual for future reference.
NOTICE: DO NOT discard this manual!
Models:
NOTE: NOT INTENDED FOR
FIREPLACE INSERT.
DO NOT PLACE ARTICLES ON OR AGAINST THIS APPLIANCE.
DO NOT USE OR STORE FLAMMABLE MATERIALS NEAR THIS APPLIANCE.
DO NOT SPRAY AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHILE IT IS IN OPERATION.
DO NOT MODIFY THIS APPLIANCE.
Installation Manual
Installation and Appliance Setup
Ref No: GMK10477
AS/NZS 5263.1.3.2016
Heat & Glo • SLR-X-AU Installation Manual • 2493-980 Rev B • 12/17
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly
could result in serious injury, death, or
property damage.
• DO NOT store or use gasoline or other flam-
mable vapors and liquids in the vicinity of this
or any other appliance.
• What to do if you smell gas
- DO NOT try to light any appliance.
- DO NOT touch any electrical switch. DO
NOT use any phone in your building.
- Leave the building immediately.
- Immediately call your gas supplier from
a neighbor's phone. Follow the gas sup-
plier's instructions.
- If you cannot reach your gas supplier, call
the fire department.
• Installation and service must be performed
by a qualified installer, service agency, or the
gas supplier.
DANGER
DO NOT TOUCH GLASS
NEVER ALLOW CHILDREN
A barrier designed to reduce the risk of
burns from the hot viewing glass is provided
with this appliance and shall be installed for
the protection of children and other at-risk
individuals.
HOT GLASS WILL
CAUSE BURNS.
UNTIL COOLED.
TO TOUCH GLASS.
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SLR-X-AU and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Heat & Glo SLR-X-AU

  • Page 1 DO NOT USE OR STORE FLAMMABLE MATERIALS NEAR THIS APPLIANCE. DO NOT SPRAY AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHILE IT IS IN OPERATION. DO NOT MODIFY THIS APPLIANCE. Heat & Glo • SLR-X-AU Installation Manual • 2493-980 Rev B • 12/17...
  • Page 2 C. Securing and Leveling the Appliance ....30 D. Non-Combustible Material Installation ....31  = Contains updated information. Heat & Glo • SLR-X-AU Installation Manual • 2493-980 Rev. B • 12/17...
  • Page 3: Installation Standard Work Checklist

    _____________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ Comments Communicated to party responsible ____________________ by ______________________on ___________ (Builder / Gen. Contractor/) (Installer) (Date)  = Contains updated information. 2493-982B 12/17 Heat & Glo • SLR-X-AU Installation Manual • 2493-980 Rev B • 12/17...
  • Page 4: A. Appliance Certification

    Gas types only through field conversions. * The allowable Outlet (Manifold) Gas Pressure ranges are: Natural Gas .80 - .95 kPa and ULPG 2.37 - 2.61 kPa. Heat & Glo • SLR-X-AU Installation Manual • 2493-980 Rev. B • 12/17...
  • Page 5: D. High Altitude Installations

    G. Electrical Codes All electrical safety testing has been done following the EN 60335-2-102 standard. Local codes apply. Heat & Glo • SLR-X-AU Installation Manual • 2493-980 Rev B • 12/17...
  • Page 6: A. Design And Installation Considerations

    Reciprocating saw Manometer Flat blade screwdriver 1/2 - 3/4 in.(13-19 mm) length, #6 or #8 Self-drilling screws Caulking material (300 ºF (149 ºC) minimum continuous exposure rating) Heat & Glo • SLR-X-AU Installation Manual • 2493-980 Rev. B • 12/17...
  • Page 7: D. Inspect Appliance And Components

    Call a qualified service technician to inspect the appliance and to replace any part of the control system and/or gas control which has been under water. Heat & Glo • SLR-X-AU Installation Manual • 2493-980 Rev B • 12/17...
  • Page 8: A. Appliance/Decorative Front Dimension Diagrams

    Inches Millimeters 16-3/4 1219 6-5/8 1092 32-3/8 39-1/16 2-3/16 15-1/4 33-11/16 17-1/4 3-1/2 25-7/8 50-1/2 1283 47-1/16 1195 9-13/16 17-3/4 10-5/8 7-3/4 37-3/4 Figure 3.1 Appliance Dimensions Heat & Glo • SLR-X-AU Installation Manual • 2493-980 Rev. B • 12/17...
  • Page 9 Dimensions are actual decorative front dimensions. Use for reference only. 40-3/16 14-1/8 45-1/8 6-7/8 9-13/16 26-7/8 SLR-X-AU CFT-42 1021 1146 Figure 3.2 Decorative Front Dimensions - CFT Heat & Glo • SLR-X-AU Installation Manual • 2493-980 Rev B • 12/17...
  • Page 10: B. Clearances To Combustibles

    TOP VENT ONE 90° ELBOW Inches 50-1/2 71-1/2 19-1/2 17-1/4 SLR-X-AU See Section 10.B for Alcove Installation. Millimeters 1283 1245 1816 Figure 3.3 Appliance Locations Heat & Glo • SLR-X-AU Installation Manual • 2493-980 Rev. B • 12/17...
  • Page 11 Appliance Appliance (Vent Pipe) (Height) (Depth) (Width) 8-5/8 33-1/8 17-3/4 SLR-X-AU 1245 * Adjust framing dimensions for interior sheathing (such as sheetrock) Figure 3.4 Clearances to Combustibles Heat & Glo • SLR-X-AU Installation Manual • 2493-980 Rev B • 12/17...
  • Page 12: C. Constructing The Appliance Chase

    • The chase must be properly blocked to prevent blown insulation or other combustibles from entering and making contact with fireplace or chimney. • Failure to maintain airspace may cause overheating and a fire. Heat & Glo • SLR-X-AU Installation Manual • 2493-980 Rev. B • 12/17...
  • Page 13: A. Vent Termination Minimum Clearances

    49.4°-53.1° ............1 830 53.1°-56.3° ............2 130 56.3°-59.0° ............2 290 59.0°-60.3° ............2 440 *910 mm minimum in snow regions Figure 4.1 Minimum Height From Roof To Lowest Discharge Opening Heat & Glo • SLR-X-AU Installation Manual • 2493-980 Rev B • 12/17...
  • Page 14: B. Chimney Diagram

    500 mm of the opening and discharging in the direction of the opening. 4. Clearance from a flue terminal to a LP cylinder shall be a minimum of 1 meter. MINIMUM CLEARANCES REQUIRED FOR BALANCED FLUE TERMINALS OR THE FLUE TERMINALS OF OUTDOOR APPLIANCES Figure 4.3 Minimum Clearances for Termination Heat & Glo • SLR-X-AU Installation Manual • 2493-980 Rev. B • 12/17...
  • Page 15: C. Approved Pipe

    SLP12 8-1/2 SLP24 SLP36 25-1/2 SLP48 1219 SLP6A 3 to 6 76 to 152 2-1/8-4-1/4 54-108 SLP12A 3 to 12 76 to 305 2-1/8-8-1/2 54-216 Figure 4.4 Heat & Glo • SLR-X-AU Installation Manual • 2493-980 Rev B • 12/17...
  • Page 16: E. Measuring Standards

    • Horizontal pipe installed level with no rise. MEASURE TO SHADED SURFACE (OUTSIDE MOUNTING SURFACE) Figure 4.6 Measure to Outside Mounting Surface Figure 4.7 Measure to Top of Last Section of Pipe Heat & Glo • SLR-X-AU Installation Manual • 2493-980 Rev. B • 12/17...
  • Page 17: F. Vent Diagrams

    • Horizontal termination cap should have a 1/4 in. (6 mm) downward slant to allow any moisture in cap to be released. See Figure 4.8. 1/4 in. max. (6 mm) Figure 4.8 Vent Cap Heat & Glo • SLR-X-AU Installation Manual • 2493-980 Rev B • 12/17...
  • Page 18 7 ft. 2.1 m 5 ft. 14 ft. 4.3 m H MAX. =14 ft. (4.3 m) V + H MAX. = 40 ft. (12.2 m) Figure 4.9 Heat & Glo • SLR-X-AU Installation Manual • 2493-980 Rev. B • 12/17...
  • Page 19 1.2 m 6 ft. 1.8 m 5 ft. 15 ft. 4.6 m MAX. =15 ft. (4.6 m) MAX. = 40 ft. (12.2 m) INSTALLED HORIZONTALLY Figure 4.10 Heat & Glo • SLR-X-AU Installation Manual • 2493-980 Rev B • 12/17...
  • Page 20 MAX. =14 ft. (4.3 m) MAX. = 40 ft. (12.2 m) *No specific restrictions on this value EXCEPT V cannot exceed 40 ft. (12.2 m) Figure 4.11 Heat & Glo • SLR-X-AU Installation Manual • 2493-980 Rev. B • 12/17...
  • Page 21 This vent configuration can ONLY be used for MAX. = 15 ft. (4.6 m) SLR-X-AU Natural Gas appliances. MAX. = 7 ft (2.1 m) INSTALLED HORIZONTALLY INSTALLED HORIZONTALLY Figure 4.12 Heat & Glo • SLR-X-AU Installation Manual • 2493-980 Rev B • 12/17...
  • Page 22 Note: Use SLP Series components only. Note: If installing a vertical vent/termination off the top of the appliance, the optional vertical termination baffle may be needed. Figure 4.13 Heat & Glo • SLR-X-AU Installation Manual • 2493-980 Rev. B • 12/17...
  • Page 23: Exhaust Restrictor

    HEAT SHIELD 3. Reinstall shield by securing it with the two wing nuts and two screws previously removed in Step 1. EXHAUST RESTRICTOR INSTALLED SCREWS Figure 4.14 Heat & Glo • SLR-X-AU Installation Manual • 2493-980 Rev B • 12/17...
  • Page 24 + H MAX. = 40 ft. (12.2 m) * No specific restrictions on this value EXCEPT V + H cannot exceed 40 ft. (12.2 m) Figure 4.15 Heat & Glo • SLR-X-AU Installation Manual • 2493-980 Rev. B • 12/17...
  • Page 25 H MAX. =14 ft. (4.3 m) MAX. = 40 ft. (12.2 m) * No specific restrictions on this value EXCEPT V cannot exceed 40 ft. (12.2 m) INSTALLED HORIZONTALLY Figure 4.16 Heat & Glo • SLR-X-AU Installation Manual • 2493-980 Rev B • 12/17...
  • Page 26 762 mm 4 ft. 1.2 m 4 ft. 1.2 m 4 ft. 1.2 m 3-1/2 ft. 1.0 m components only. Maximum= 40 ft. (12.2 m) Figure 4.17 Heat & Glo • SLR-X-AU Installation Manual • 2493-980 Rev. B • 12/17...
  • Page 27: A. Pipe Clearances To Combustibles

    * Shows center of vent framing hole for top or rear venting. The center of the hole is 1 in. (25 mm) above the center of the horizontal vent pipe. Figure 5.2 Wall Penetration Heat & Glo • SLR-X-AU Installation Manual • 2493-980 Rev B • 12/17...
  • Page 28: C. Ceiling Firestop/Floor Penetration Framing

    INSTALL ATTIC INSULATION SHIELDS BEFORE OR AFTER INSTALLATION OF VENT SYSTEM CEILING FIRESTOP CEILING FIRESTOP INSTALLED BELOW CEILING INSTALLED ABOVE CEILING Figure 5.4 Installing the Attic Shield Heat & Glo • SLR-X-AU Installation Manual • 2493-980 Rev. B • 12/17...
  • Page 29: A. Vent Collar Preparation

    Figure 6.1 Shipping Position TOP HEAT HEAT-ZONE -240V ® SHIELD IN ATTACHES HERE POSITION (RIGHT & LEFT SIDES) Figure 6.2 Top Heat Shield in Position and Heat-Zone -240V Locations ® Heat & Glo • SLR-X-AU Installation Manual • 2493-980 Rev B • 12/17...
  • Page 30: C. Securing And Leveling The Appliance

    • Optional: Secure the appliance to the floor by inserting two screws through the pilot holes at the bottom of the appliance. Heat & Glo • SLR-X-AU Installation Manual • 2493-980 Rev. B • 12/17...
  • Page 31: D. Non-Combustible Material Installation

    Refer to Section THESE PILOT HOLES 10 for more information. NOTE: BOTH LEFT & RIGHT SIDES Figure 6.5 Proper Positioning, Leveling And Securing Of Appliance Heat & Glo • SLR-X-AU Installation Manual • 2493-980 Rev B • 12/17...
  • Page 32: A . Assemble Vent Sections

    Use care when remov- ing termination cap from slip pipe. If slip section seals are broken during removal of the termination cap, vent could leak. Heat & Glo • SLR-X-AU Installation Manual • 2493-980 Rev. B • 12/17...
  • Page 33: B. Assemble Slip Sections

    NOTICE: If slip section is too long, the inner and outer flues of the slip section can be cut to the desired length. Figure 7.6 Securing Horizontal Pipe Sections Heat & Glo • SLR-X-AU Installation Manual • 2493-980 Rev B • 12/17...
  • Page 34: D. Disassemble Vent Sections

    Figure 7.8. • Pull carefully to separate the pieces of pipe. Figure 7.7 Rotate Seams for Disassembly Figure 7.8 Align and Disassemble Vent Sections Heat & Glo • SLR-X-AU Installation Manual • 2493-980 Rev. B • 12/17...
  • Page 35: E. Vertical Termination Requirements

    • Caulk the perimeter of the flashing where it contacts the roof surface. See Figure 7.10. • Caulk the overlap seam of any exposed pipe sections that are located above the roof line. Heat & Glo • SLR-X-AU Installation Manual • 2493-980 Rev B • 12/17...
  • Page 36: F. Horizontal Termination Requirements

    • Rest the small leg on the extended heat shield on top of the pipe section to properly space it from the pipe section. Important Notice: Heat shields may not be fi eld constructed. Figure 7.12 Heat & Glo • SLR-X-AU Installation Manual • 2493-980 Rev. B • 12/17...
  • Page 37 CAUTION! Risk of Burns! Local codes may require in- OUTER VENT stallation of a cap shield to prevent anything or anyone INTERIOR EXTERIOR from touching the hot cap. Figure 7.13 Venting Through the Wall Heat & Glo • SLR-X-AU Installation Manual • 2493-980 Rev B • 12/17...
  • Page 38: A. General Information

    Figure 8.2 Gas Valve, Backup Battery, Control Module & Wiring for optional Hearth & Home Technologies approved AUX300CE accessories should be done now to avoid reconstruction. Follow instructions that come with those accessories. Heat & Glo • SLR-X-AU Installation Manual • 2493-980 Rev. B • 12/17...
  • Page 39: B. Wiring Requirements

    TRANSFORMER GAS VALVE JUNCTION CORD WIRE HARNESS AUX MODULE RED WIRE BLACK WIRE GREEN WIRE BATTERY PACK ORANGE WIRE Figure 8.3 IntelliFire™ Plus Wiring Diagram with Remote Heat & Glo • SLR-X-AU Installation Manual • 2493-980 Rev B • 12/17...
  • Page 40: A. Fuel Conversion

    Access Through the Valve Assembly 1. Locate and remove the two screws that secure the base pan to the appliance. See Figure 9.1. Remove base pan. Retain screws. Heat & Glo • SLR-X-AU Installation Manual • 2493-980 Rev. B • 12/17...
  • Page 41 Remove glass assembly and utilize an appropriate sized screwdriver. See Figure 8.2. REMOVE PILOT SCREWS REMOVE BURNER SCREW Figure 9.2 Burner Removal Heat & Glo • SLR-X-AU Installation Manual • 2493-980 Rev B • 12/17...
  • Page 42: D. Gas Connection

    Log Option SLR-X-AU (NG) 1/8 in. (3 mm) 1/2 in. (13 mm) SLR-X-AU (LP) Full Open 3/8 in. (10 mm) SLR-X-AU (B) Full Open 5/8 in. (16 mm) Heat & Glo • SLR-X-AU Installation Manual • 2493-980 Rev. B • 12/17...
  • Page 43: A. Facing Materials

    • Facing and/or finishing materials must not interfere with air flow through louvers or decorative fronts. • Facing and/or finishing materials must never overhang into the glass opening. Heat & Glo • SLR-X-AU Installation Manual • 2493-980 Rev B • 12/17...
  • Page 44: B. Non-Combustible Board And Drywall Installation

    (254 mm) on the sides of the fireplace. 5. To ensure good adhesion of drywall compounds and tape, thoroughly clean the non-combustible board and surrounding drywall to remove dust. Heat & Glo • SLR-X-AU Installation Manual • 2493-980 Rev. B • 12/17...
  • Page 45 Note: It is acceptable to use a silicone sealant with a minimum of 300 ºF (149 ºC) continuous exposure rating to adhere drywall to lower cover panel. Figure 10.2 Finishing Details Heat & Glo • SLR-X-AU Installation Manual • 2493-980 Rev B • 12/17...
  • Page 46: C. Mantel And Wall Projections

    MANTEL TO TOP OF APPLIANCE OPENING APPLIANCE OPENING Figure 10.4 Clearances To Non-Combustible Mantels Or Other Non-Combustibles Above Appliance Figure 10.3 Clearances To Combustibles Mantels Or Other Combustibles Above Appliance Heat & Glo • SLR-X-AU Installation Manual • 2493-980 Rev. B • 12/17...
  • Page 47 (178 mm) MIN. WALL APPLIANCE OPENING UNLIMITED Figure 10.6 Combustible or Non-Combustible Mantel Leg or Wall Projections - Unlimited Wall Length (Acceptable on both sides of opening) Heat & Glo • SLR-X-AU Installation Manual • 2493-980 Rev B • 12/17...
  • Page 48: D. Decorative Front Finishing

    Figure 10.7 Overlap Fit Decorative Front (CFT Decorative Front) OUTER DOOR TRIM INNER DOOR ASSEMBLY TOP VANITY PANEL (NOT SHOWN) Figure 10.9 CFT Front Installation With Outer Door Trim Heat & Glo • SLR-X-AU Installation Manual • 2493-980 Rev. B • 12/17...
  • Page 49 (BOTH SIDES) (BOTH SIDES) Figure 10.10 CFT Front Without Outer Door Trim Heat & Glo • SLR-X-AU Installation Manual • 2493-980 Rev B • 12/17...
  • Page 50: A. Remove Fixed Glass Assembly

    Remove the splatter guard before lighting the appliance. C. Clean the Appliance Clean/vacuum any sawdust that may have accumulated Figure 11.1 Fixed Glass Assembly inside the firebox or underneath in the control cavity. Heat & Glo • SLR-X-AU Installation Manual • 2493-980 Rev. B • 12/17...
  • Page 51: E. Install Media Option

    Glass latches MUST be properly engaged. Inspect glass seal before installing decorative front. Gas could leak! 5. Reinstall decorative front. Heat & Glo • SLR-X-AU Installation Manual • 2493-980 Rev B • 12/17...
  • Page 52: G. Install Fan Brackets

    Contact your dealer or Hearth & Home Technologies if the barrier is not present or help is needed to properly install one. For more information refer to the instructions supplied with your decorative front. Heat & Glo • SLR-X-AU Installation Manual • 2493-980 Rev. B • 12/17...
  • Page 53: A. Vent Components Diagrams

    1-1/2 in. 12 in. 5-1/2 in. 220 mm 38 mm 305 mm 146 mm SLP-WS SLP-FS Wall Shield Firestop Ceiling Firestop Figure 12.1 SLP Series Vent Components Heat & Glo • SLR-X-AU Installation Manual • 2493-980 Rev B • 12/17...
  • Page 54 DVP-HSM-B SL-2DVP Extended Heat Shield Adapter 14-7/16 in. 367 mm 2-5/16 in. 14-7/16 in. 59 mm 367 mm SLP-WT-BK Wall Thimble-Black Figure 12.2 SLP Series Vent Components Heat & Glo • SLR-X-AU Installation Manual • 2493-980 Rev. B • 12/17...
  • Page 55 7-3/4 to 10-3/8 in. (197 to 264 mm) 12 IN. DVP-FBHT 305 mm Horizontal SLP-TB1 Termination Cap Basement Vent Cap (SL-2DVP Required) Figure 12.3 SLP Series Vent Components Heat & Glo • SLR-X-AU Installation Manual • 2493-980 Rev B • 12/17...
  • Page 56 (213 mm) 3° 87° 15 in. 10-1/2 in. (381 mm) (267 mm) 10-7/8 in. (276 mm) SLP-HRC-SS SLP-HRC-ZC-SS HORIZONTAL TERMINATION CAP Figure 12.4 SLP series Vent Components Heat & Glo • SLR-X-AU Installation Manual • 2493-980 Rev. B • 12/17...
  • Page 57: B. Accessories

    Please contact your Heat & Glo dealer with any questions or concerns. For the location of your nearest Heat & Glo dealer, please visit www.heatnglo.com. Printed in U.S.A. - Copyright 2017 Heat & Glo • SLR-X-AU Installation Manual • 2493-980 Rev B • 12/17...

Table of Contents