Heat & Glo SLR-X-AU Installation Manual page 11

Hide thumbs Also See for SLR-X-AU:
Table of Contents

Advertisement

Framing
This appliance is designed to be recessed into combus-
tible framing with non-combustible material pre-installed
on top and side. Drywall or combustible materials (mini-
mum 1/2 in. (13 mm) thick) are designed to contact the
non-combustible material/appliance as called out in Sec-
tion 10 Finishing.
This appliance has been thoroughly tested to minimize
drywall cracking and/or the protrusion of screws "screw
pops" when framed as shown above.
Framing should be done in a manner similar to framing
a window or door: double - 2 x 4 / 2 x 6 (610 x 1219
mm / 610 x 1829 mm) as a Header for horizontal strength
and untilizing Jack or Trimmer Stud fastened to the King
Studs for vertical strength.
If elevating the appliance, the base of the unit should also
be constructed in a similar manner to prevent settling.
HEADER: TWO 2 X 4'S OR 2 X 6'S
(610 x 1219 mm or 610 x 1829 mm)
INSTALLED ON END
JACK (TRIMMER) STUD
Models
in.
SLR-X-AU
mm
* Adjust framing dimensions for interior sheathing (such as sheetrock)
Figure 3.4 Clearances to Combustibles
A
B
C
D
KING STUD
A
B
C
Rough
Rough
Rough
Opening
Opening
Opening
(Vent Pipe)
(Height)
(Depth)
8-5/8
33-1/8
17-3/4
219
841
451
Heat & Glo • SLR-X-AU Installation Manual • 2493-980 Rev B • 12/17
Note: Refer to Section 10 for important information
related to facing, drywall specifications and decorative
front information.
*MINIMUM FRAMING DIMENSIONS
D
E
Rough
Clearance
Combustible
Opening
to Ceiling
Floor
(Width)
49
31
1245
787
MEASURE FROM TOP
OF APPLIANCE OPENING
G
J
F
G
H
Combustible
Behind
Flooring
Appliance
0
0
1/2
0
0
13
E
H
I
I
J
Sides of
Front of
Appliance
Appliance
1/2
36
13
914
11

Advertisement