A. Appliance Certification - Heat & Glo SLR-X-AU Installation Manual

Hide thumbs Also See for SLR-X-AU:
Table of Contents

Advertisement

1
Product Specific and Important Safety Information

A. Appliance Certification

MODEL: SLR-X-AU
LABORATORY: IAMPO OCEANA
TYPE: Direct Vent Heater
STANDARD: AS/NZS 5263.1.3:2016
The Heat & Glo gas appliances discussed in this Installer's
Guide have been tested to certification standards and listed
by the applicable laboratories.
This appliance must be installed in accordance with the
rules in force.
NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE.
This appliance is tested and approved as either supplemen-
tal room heat or as a decorative appliance. It should not be
factored as primary heat in residential heating calculations.
B. Glass Specifications
This appliance is equipped with 5 mm ceramic glass. Re-
place glass only with 5 mm ceramic glass. Please contact
your dealer for replacement glass.
Inlet Gas Pressure
* Outlet (Manifold) Gas Pressure
Gas Rate
Maximum Gas Consumption
Burner Injector
Pilot Injector
Gas types only through field conversions.
* The allowable Outlet (Manifold) Gas Pressure ranges are: Natural Gas .80 - .95 kPa and ULPG 2.37 - 2.61 kPa.
4
Natural Gas
1.13 - 3.40 kPa
.87 kPa
.405
/
m3
h
31.65 MJ/h
#37 DMS (2.64 mm)
Ø .023 (.584 mm)
Heat & Glo • SLR-X-AU Installation Manual • 2493-980 Rev. B • 12/17
C. Gas Pressure Requirements
Pressure requirements for SLR-X-AU fireplaces are
shown in table below.
Two taps are provided on the right hand side of the gas
control for a test gauge connection to measure the inlet
and outlet pressures.
The fireplace and its individual shut-off valve must be dis-
connected from the gas supply piping system during any
pressure testing of the system at test pressures in excess
of 3.4 kPa.
If the fireplace must be isolated from the gas supply pip-
ing system by closing an individual shut-off valve, it must
be of the handle-less type.
Propane
2.75 - 3.40 kPa
2.40 kPa
.134
/
m3
h
27.43 MJ/h
#53 DMS (1.51 mm)
Ø .014 (.356 mm)
Butane
2.75 - 3.40 kPa
2.40 kPa
.111
/
m3
h
25.30 MJ/h
.057 DMS (1.45 mm)
Ø .010 (.254 mm)