Heat & Glo SLR-D Owner's Manual

Heat & Glo SLR-D Owner's Manual

Vented gas fireplace heaters
Table of Contents

Advertisement

Model:
SLR-D (COSMO)
• Important operating
a n d m a i n t e n a n c e
instructions included.
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly
could result in serious injury, death, or
property damage.
• DO NOT store or use gasoline or other flam-
mable vapors and liquids in the vicinity of this
or any other appliance.
• What to do if you smell gas
- DO NOT try to light any appliance.
- DO NOT touch any electrical switch. DO
NOT use any phone in your building.
- Leave the building immediately.
- Immediately call your gas supplier from
a neighbor's phone. Follow the gas sup-
plier's instructions.
- If you cannot reach your gas supplier, call
the fire department.
• Installation and service must be performed
by a qualified installer, service agency, or the
gas supplier.
In the Commonwealth of Massachusetts installation must be
performed by a licensed plumber or gas fitter.
See Table of Contents for location of additional Commonwealth
of Massachusetts requirements.
NOTICE
DO NOT DISCARD THIS MANUAL
• Read, understand and follow
these instructions for safe
installation and operation.
Heat & Glo • SLR-D • 2333-900 Rev. F • 9/17
Owner's Manual
Installation and Operation
• Leave this manual with
party responsible for use
and operation.
DANGER
HOT GLASS WILL
DO NOT TOUCH GLASS
NEVER ALLOW CHILDREN
TO TOUCH GLASS.
A barrier designed to reduce the risk of
burns from the hot viewing glass is provided
with this appliance and shall be installed for
the protection of children and other at-risk
individuals.
This appliance may be installed as an OEM
installation in manufactured home (USA
only) or mobile home and must be installed
in accordance with the manufacturer's
instructions and the Manufactured Home
Construction and Safety Standard, Title 24
CFR, Part 3280 in the United States, or the
Standard for Installation in Mobile Homes,
CAN/CSA Z240 MH Series, in Canada.
This appliance is only for use with the type(s)
of gas indicated on the rating plate. This
appliance is not convertible for use with other
gases, unless a certified kit is used.
CAUSE BURNS.
UNTIL COOLED.
1

Advertisement

Table of Contents
loading

Summary of Contents for Heat & Glo SLR-D

  • Page 1 See Table of Contents for location of additional Commonwealth appliance is not convertible for use with other of Massachusetts requirements. gases, unless a certified kit is used. Heat & Glo • SLR-D • 2333-900 Rev. F • 9/17...
  • Page 2: Congratulations

    BTUH: 00,000 00,000 00,000 00,000 MIN. MIN. INPUT INPUT BTUH: BTUH: 00,000 00,000 00,000 00,000 Serial Serial XXXXXXXX XXXXXXXX ORIFICE ORIFICE SIZE: SIZE: #XXXXX #XXXXX #XXXXX #XXXXX (Serie): (Serie): Heat & Glo • SLR-D • 2333-900 Rev. F • 9/17...
  • Page 3: Table Of Contents

    E. Junction Box Installation......50 Heat & Glo • SLR-D • 2333-900 Rev. F • 9/17...
  • Page 4 D. Contact Information ......74  = Contains updated information. Heat & Glo • SLR-D • 2333-900 Rev. F • 9/17...
  • Page 5: Limited Lifetime Warranty

    3 years Firebox and heat exchanger Lifetime All replacement parts 90 Days beyond warranty period See conditions, exclusions, and limitations on next page. 4021-645H 10/15 Page 1 of 2 Heat & Glo • SLR-D • 2333-900 Rev. F • 9/17...
  • Page 6 THE EXTENT PROVIDED BY LAW, HHT MAKES NO EXPRESS WARRANTIES OTHER THAN THE WARRANTY SPECIFIED HEREIN. THE DURATION OF ANY IMPLIED WARRANTY IS LIMITED TO DURATION OF THE EXPRESSED WARRANTY SPECIFIED ABOVE. 4021-645H 10/15 Page 2 of 2 Heat & Glo • SLR-D • 2333-900 Rev. F • 9/17...
  • Page 7: Listing And Code Approvals

    • A 110-120 VAC circuit for this product must be protected with ground-fault circuit-interrupter protection, in compliance with the applicable electrical codes, when it is installed in locations such as in bathrooms or near sinks. Heat & Glo • SLR-D • 2333-900 Rev. F • 9/17...
  • Page 8: Requirements For The Commonwealth Of Massachusetts

    VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OB- of the installation. STRUCTIONS”. See Gas Connection section for additional Common- wealth of Massachusetts requirements. Heat & Glo • SLR-D • 2333-900 Rev. F • 9/17...
  • Page 9: User Guide

    • Install a switch lock or a wall/remote control with child protection lockout feature. • Keep remote controls out of reach of children. Heat & Glo • SLR-D • 2333-900 Rev. F • 9/17...
  • Page 10: Clear Space

    Contact your dealer or Hearth & Home Technologies if the barrier is not present or help is needed to properly install one. For more information refer to the instructions supplied with your decorative door or front. Heat & Glo • SLR-D • 2333-900 Rev. F • 9/17...
  • Page 11: Lighting Instructions (Ipi)

    Keep burner and control compartment clean. See installation and operating instruc- Propane Installation code, CSA B149.1. tions accompanying appliance. For additional information on operating your 593-913i Hearth & Home Technologies fi replace, please refer to www.fi replaces.com. Heat & Glo • SLR-D • 2333-900 Rev. F • 9/17...
  • Page 12: After Fireplace Is Lit

    Wall above appliance feels hot to No action necessary. This appliance ships with a non-combustible material attached. Specifica- the touch. tions of the attached non-combustible material are listed in Section 1.E. Heat & Glo • SLR-D • 2333-900 Rev. F • 9/17...
  • Page 13: Maintenance And Service

    • Inspect draft shield to verify it is not damaged or missing. • Refer to Section 14.F for glass removal and replacement instructions. • Reinstall door or decorative front. Heat & Glo • SLR-D • 2333-900 Rev. F • 9/17...
  • Page 14: Maintenance Tasks-Qualified Service Technician

    Use caution when cleaning these areas. Screw tips that have penetrated the sheet metal are sharp and should be avoided. • Remove all foreign objects. • Verify unobstructed air circulation. Figure 3.1 IPI Pilot Flame Pattern Heat & Glo • SLR-D • 2333-900 Rev. F • 9/17...
  • Page 15: Installer Guide

    CEILING FIRESTOP ON FLOOR OF ATTIC (SECTION 8.C) FRAMING HEADED OFF IN CEILING JOISTS (SECTION 8.C) FRAMING/HEADER (SECTION 5) WALL SWITCH GAS LINE (SECTION 11) Figure 4.1 Typical System Heat & Glo • SLR-D • 2333-900 Rev. F • 9/17...
  • Page 16: Design And Installation Considerations

    Plumb line Safety glasses Level Reciprocating saw Manometer Flat blade screwdriver 1/2 - 3/4 in. length, #6 or #8 Self-drilling screws Caulking material (300 ºF minimum continuous exposure rating) Heat & Glo • SLR-D • 2333-900 Rev. F • 9/17...
  • Page 17: Framing And Clearances

    TOP VENT ONE 90 ELBOW TOP VENT ONE 90° ELBOW Inches 53-1/32 19-9/32 17-3/4 See Section D. Figure 5.5 & 5.6 Millimeters 1347 1219 1905 Figure 5.1 Appliance Locations Heat & Glo • SLR-D • 2333-900 Rev. F • 9/17...
  • Page 18: Constructing The Appliance Chase

    Heat & Glo • SLR-D • 2333-900 Rev. F • 9/17...
  • Page 19: Clearances

    Appliance (Vent Pipe) (Height) (Depth) (Width) Inches 8-5/8 40 1/4 18-1/4 Millimeters 1023 1270 * Adjust framing dimensions for interior sheathing (such as sheetrock) Figure 5.2. Clearances to Combustibles Heat & Glo • SLR-D • 2333-900 Rev. F • 9/17...
  • Page 20: Mantel And Wall Projections

    NAILING TAB Non-Combustibles Above Appliance 1/2 IN. FACTORY-SUPPLIED NON-COMBUSTIBLE BOARD Note: For non-combustible fireplace finish material (marble, stone, etc) specifications refer to Section 13.C. Figure 5.7 Front Side Finishing Detail Heat & Glo • SLR-D • 2333-900 Rev. F • 9/17...
  • Page 21 3-1/2 IN. NON-COMBUSTIBLE BOARD SHIPPED WITH APPLIANCE 1 IN. 1 IN. AIR SPACE Figure 5.8 Non-Combustible Zone Heat & Glo • SLR-D • 2333-900 Rev. F • 9/17...
  • Page 22: Termination Locations

    Over 16/12 to 18/12 ..........7.0 Over 18/12 to 20/12 ..........7.5 Over 20/12 to 21/12 ..........8.0 * 3 foot minimum in snow regions Figure 6.1 Minimum Height From Roof To Lowest Discharge Opening Heat & Glo • SLR-D • 2333-900 Rev. F • 9/17...
  • Page 23 Figure 6.3 Minimum Clearances for Termination • Vinyl protection kits are suggested for use with vinyl siding. Heat & Glo • SLR-D • 2333-900 Rev. F • 9/17...
  • Page 24: Vent Information And Diagrams

    • Horizontal runs of vent do not require vertical rise; horizontal runs may be level. Horizontal • Horizontal termination cap should have a 1/4 inch downward slant to allow any moisture in cap to be Figure 7.1 released. Heat & Glo • SLR-D • 2333-900 Rev. F • 9/17...
  • Page 25 CAUTION: The SLP-HRC-SS termination cap is not approved for use with propane (LP) fuel. May lead to elevated glass temperature that may cause tem- pered glass breakage. Figure 7.4 Heat & Glo • SLR-D • 2333-900 Rev. F • 9/17...
  • Page 26 CAUTION: The SLP-HRC-SS termination cap is not approved for use with propane (LP) fuel. May lead to elevated glass temperature that may cause tem- pered glass breakage. INSTALLED HORIZONTALLY Figure 7.5 Heat & Glo • SLR-D • 2333-900 Rev. F • 9/17...
  • Page 27 CAUTION: The SLP-HRC-SS termination cap is not approved for use with propane (LP) fuel. May lead to elevated glass temperature that may cause tem- pered glass breakage. Figure 7.6 Heat & Glo • SLR-D • 2333-900 Rev. F • 9/17...
  • Page 28 CAUTION: The SLP-HRC-SS termination cap is not approved for use with propane (LP) fuel. May lead to elevated glass temperature that may cause tem- pered glass breakage. INSTALLED HORIZONTALLY INSTALLED HORIZONTALLY Figure 7.7 Heat & Glo • SLR-D • 2333-900 Rev. F • 9/17...
  • Page 29 If the vent configuration has a total ver- tical of 15-44 feet, an exhaust restrictor may be needed. The exhaust restrictor can be located in the appliance manual bag. Heat & Glo • SLR-D • 2333-900 Rev. F • 9/17...
  • Page 30 Note: There MUST be a 25% reduction in total H when using flex vent except when using the simple up and out installation (see Figure 7.17). Figure 7.11 Heat & Glo • SLR-D • 2333-900 Rev. F • 9/17...
  • Page 31 Note: There MUST be a 25% reduction in total H when using flex vent except when using the simple up and out installation (see Figure 7.17). INSTALLED HORIZONTALLY Figure 7.12 Heat & Glo • SLR-D • 2333-900 Rev. F • 9/17...
  • Page 32 Maximum= 40 ft. (12.2 m) Note: There MUST be a 25% reduction in total H when using flex vent except when using the simple up and out installation (see Figure 7.17). Figure 7.13 Heat & Glo • SLR-D • 2333-900 Rev. F • 9/17...
  • Page 33 CAUTION! DO NOT use any flue restrictor when vent- ing with the DV-46DVA-GCL adapter and LINK-DV30B kit. This may result in poor flame appearance, sooting, pilot malfunction, or overheating. Heat & Glo • SLR-D • 2333-900 Rev. F • 9/17...
  • Page 34 VENT PIPE EXISTING CHIMNEY To minimize cold air drafts, seal with non-combustible insulation. DIRECT VENT FIREPLACE Minimum 10 ft. 3.05 m Maximum 40 ft. 12.2 m HEARTH FLOOR Figure 7.16 Heat & Glo • SLR-D • 2333-900 Rev. F • 9/17...
  • Page 35: Use Of Flex Vent

    However, the vent attachment point and the firestop location are considered to be supports. TERMINATION 3 in. CLEARANCE FLEX-VENT 1 in. CLEARANCE Figure 7.17 Flex Vent Pipe - Generic Fireplace Shown Heat & Glo • SLR-D • 2333-900 Rev. F • 9/17...
  • Page 36: Vent Clearances And Framing

    * Shows center of vent framing hole for top venting. The center of the hole is one (1) in. (25.4 mm) above the center of the horizontal vent pipe. Figure 8.2 Wall Penetration Heat & Glo • SLR-D • 2333-900 Rev. F • 9/17...
  • Page 37: Install The Ceiling Firestop

    Figure 8.3 Installing Ceiling Firestop INSTALL ATTIC INSULATION SHIELDS BEFORE OR AFTER INSTALLATION OF VENT SYSTEM CEILING FIRESTOP CEILING FIRESTOP INSTALLED BELOW CEILING INSTALLED ABOVE CEILING Figure 8.4 Installing the Attic Shield Heat & Glo • SLR-D • 2333-900 Rev. F • 9/17...
  • Page 38: Installing The Optional Heat-Zone ® Gas Or

    • Determine the location for the air register/fan housing assembly. Reference the Heat-Zone Gas Kit or Heat-Zone Plus ® ® Kit instructions for the remaining installation steps. HEAT-ZONE ® ATTACHES HERE Figure 8.5 Heat-Zone Locations ® Heat & Glo • SLR-D • 2333-900 Rev. F • 9/17...
  • Page 39: Appliance Preparation

    For all venting applications, ensure that the pipe gasket is in place before attaching any pipe section. This gasket is shipped in place around the starting collar. See Figure 9.2. Heat & Glo • SLR-D • 2333-900 Rev. F • 9/17...
  • Page 40: Securing And Leveling The Appliance

    Figure 9.3 shows the fireplace installed on the floor. However, this fireplace can be elevated off the floor provided that the fireplace is properly supported by framing materials and the ceiling clearances are maintained. Heat & Glo • SLR-D • 2333-900 Rev. F • 9/17...
  • Page 41: Installing Vent Pipe (Slp Pipe)

    Use care when removing termination cap from slip pipe. If slip section seals are broken during removal of the termination cap, vent may leak. Heat & Glo • SLR-D • 2333-900 Rev. F • 9/17...
  • Page 42: Assemble Slip Sections

    • Only outer pipes are sealed, sealing the inner flue is not required. • All unit collar, pipe, slip section, elbow and cap outer flues shall be sealed. Heat & Glo • SLR-D • 2333-900 Rev. F • 9/17...
  • Page 43: Disassemble Vent Sections

    1/8 in. (3 mm) larger than the support box outline. • Lower the support box through the hole in the roof until its bottom is at least 2 in. (51 mm) below the ceiling (Figure Heat & Glo • SLR-D • 2333-900 Rev. F • 9/17...
  • Page 44: Install Metal Roof Flashing

    • Caulk the perimeter of the flashing where it contacts the roof surface. See Figure 10.12. • Caulk the overlap seam of any exposed pipe sections that are located above the roof line. Heat & Glo • SLR-D • 2333-900 Rev. F • 9/17...
  • Page 45: Install Vertical Termination Cap

    • Once the pipe section and the termination cap have been connected, slide the wall thimble up to the interior wall surface and attach with screws provided. See Figure 10.15. Figure 10.15 Wall Thimble Heat & Glo • SLR-D • 2333-900 Rev. F • 9/17...
  • Page 46: Install Horizontal Termination Cap

    1-1/2 IN. (38 MM) MIN. HEAT SHIELD OVERLAP WALL SHIELD FIRESTOP SLIP SECTION CAN BE EXTENDED INNER VENT SHEATHING OUTER VENT INTERIOR EXTERIOR Figure 10.16 Venting through the wall Heat & Glo • SLR-D • 2333-900 Rev. F • 9/17...
  • Page 47: Gas Information

    The lower access cover panel is removable if finishing fitting. See Figure 11.4. material has not been previously installed. Heat & Glo • SLR-D • 2333-900 Rev. F • 9/17...
  • Page 48: Gas Connection

    Note: The manifold and inlet pressure tabs can be ac- between 2000 feet and 4500 feet. Above 4500 feet, cessed from the front of the fireplace when valve assembly consult local gas utility. is installed. Heat & Glo • SLR-D • 2333-900 Rev. F • 9/17...
  • Page 49: Electrical Information

    3 volt system. • Plug the 3-volt AC transformer into the appliance junction GAS VALVE CONTROL MODULE AC ADAPTER CONTROL MODULE GROUND BATTERY PACK Figure 12.1 Valve Cavity Heat & Glo • SLR-D • 2333-900 Rev. F • 9/17...
  • Page 50: Electrical Service And Repair

    6. Reinstall the junction box. 7. Reposition the junction box heat shield such that it is positioned over the junction box. Heat & Glo • SLR-D • 2333-900 Rev. F • 9/17...
  • Page 51: Finishing

    Ensure that the 1 inch air space clearance is main- tained on the sides of the fireplace. See Figure 13.2. NAILING TAB 1/2 IN. FACTORY-SUPPLIED NON-COMBUSTIBLE BOARD Figure 13.2 Front Side Finishing Detail Heat & Glo • SLR-D • 2333-900 Rev. F • 9/17...
  • Page 52 Self-tapping screws up to one inch long can be installed through the nailing tab and outer 3 inch edges of the factory-installed non-combustible board to secure the drywall adjacent to the factory-installed non-combustible board. See Figure 13.3. Heat & Glo • SLR-D • 2333-900 Rev. F • 9/17...
  • Page 53 1-1/4 in. long screw fasteners, located within 1-1/2 in. from each corner, and at no more than 12 inch intervals along the joint length. Heat & Glo • SLR-D • 2333-900 Rev. F • 9/17...
  • Page 54: Mantel And Wall Projections

    14 IN. FIREPLACE MIN. OPENING See Dimension T on Appliance Dimension Diagram (Figure 16.1). 1 IN.MIN. 4 IN. MAX. Figure 13.6 Clearances To Non-Combustible Mantels Or Other Non-Combustibles Above Appliance Heat & Glo • SLR-D • 2333-900 Rev. F • 9/17...
  • Page 55: Facing Material

    0 - 1 IN. THICK DECORATIVE FRONT SHOWN NON-COMBUSTIBLE FINISHING MATERIAL 0 - 1 IN. THICK DRYWALL OR EQUIVALENT (1/2 IN.) Figure 13.9 Overlap Fit Method (Tonic or Martini Decorative Front) Heat & Glo • SLR-D • 2333-900 Rev. F • 9/17...
  • Page 56 0 - 4 IN. 3/4 IN. (TON-SLR-**) 20-1/2 IN. 3-1/4 IN. (TON-SLR-**) 0 - 4 IN. DRYWALL OR EQUIVALENT (1/2 IN.) Figure 13.10 Inside Fit Method (Tonic Decorative Front Only) Heat & Glo • SLR-D • 2333-900 Rev. F • 9/17...
  • Page 57: Decorative Fronts

    13 in. 330 mm (height). Outside dimension of decorative 19-1/2 in. 495 mm Overlap Fit Only front (height). See Section 13.C. MARTINI DECORATIVE FRONT (MAR-SLR-**) Figure 13.13 Martini Decorative Front Heat & Glo • SLR-D • 2333-900 Rev. F • 9/17...
  • Page 58 (width). Outside dimension of 18-7/8 IN. 479 mm decorative front (height). Inside dimension decorative 40-1/4 IN. 1022 mm front (width) Inside dimension decorative 13-1/4 IN. 337 mm front (height) Heat & Glo • SLR-D • 2333-900 Rev. F • 9/17...
  • Page 59: Appliance Setup

    DO NOT install glass rock media in the outlined area. This may cause delayed ignition, undesirable burner flame, or lighting issues. Figure 14.2. Installing Glass Rock Media Heat & Glo • SLR-D • 2333-900 Rev. F • 9/17...
  • Page 60 Blocking this gap may cause an undesirable flame appearance. See Figure 14.4. NO GLASS ROCK MEDIA BETWEEN DASHED LINES. Figure 14.4. Maintaining Media Tray Air Spaces. Heat & Glo • SLR-D • 2333-900 Rev. F • 9/17...
  • Page 61: Fixed Glass Assembly

    UPPER SPRING LATCH LOWER GLASS CLIP Figure 14.6 Air Shutter Air Shutter Settings SLR-D 3/16 in. 9/16 in. Figure 14.5 Fixed Glass Assembly Heat & Glo • SLR-D • 2333-900 Rev. F • 9/17...
  • Page 62: Troubleshooting

    Verify module is securely grounded to metal chassis of appliance. d. Module voltage output / Valve/Pilot Verify battery voltage is at least 2.7 volts. Replace batteries if volt- solenoid ohms readings. age is below 2.7. Heat & Glo • SLR-D • 2333-900 Rev. F • 9/17...
  • Page 63 ON position. If there is no spark at “I” terminal module must be replaced. If there is a spark at “I” terminal, module is fine. Heat & Glo • SLR-D • 2333-900 Rev. F • 9/17...
  • Page 64: Reference Materials

    Inches Millimeters 37-3/4 1219 16-3/4 1092 6-5/8 39-1/16 13-1/4 39-3/4 1010 1042 2-3/16 3-9/16 17-1/4 6-7/8 18-1/4 45-1/16 1145 25-7/8 9-5/16 9-3/4 17-3/4 51-1/2 1308 Figure 16.1 Appliance Dimensions Heat & Glo • SLR-D • 2333-900 Rev. F • 9/17...
  • Page 65: Vent Components Diagrams

    1-1/2 in. 8-7/8 in. 12 in. 5-1/2 in. 38 mm 225 mm 146 mm 305 mm SLP-WS SLP-HVS Wall Shield Firestop Horizontal Pipe Support Figure 16.2 SLP Series Vent Components Heat & Glo • SLR-D • 2333-900 Rev. F • 9/17...
  • Page 66 (101 mm) (97 mm) 10-9/16 in. 5-1/16 in. 269 mm 8 in. (128 mm) (203 mm) SLP-CCS-BK Cathedral Ceiling SL-2DVP Support Box-Black Adapter Figure 16.3 SLP Series Vent Components Heat & Glo • SLR-D • 2333-900 Rev. F • 9/17...
  • Page 67 (LP) fuel. SLP-HRC-SS HORIZONTAL TERMINATION CAP 12 IN. 305 mm 7 IN. 178 mm 15-1/2 IN. 394 mm DVP-FBHT SLP90 SL-2DVP DVP-FBHT Figure 16.4 SLP Series Vent Components Heat & Glo • SLR-D • 2333-900 Rev. F • 9/17...
  • Page 68 (233 mm) 13-5/8 16-11/16 IN. 16-11/16 IN. (346 mm) 424 mm (424 mm) 12-1/2 IN. (318 mm) SLP-LPC SLP Low Profile Cap (Approved for use with PVI-SLP-B only) Figure 16.5 PVI-SLP-B Vent Components Heat & Glo • SLR-D • 2333-900 Rev. F • 9/17...
  • Page 69 60 FT PV Wire Harness PVI-WH60 80 FT PV Wire Harness PVI-WH80 100 FT PV Wire Harness PVI-WH100 PVLP-HS Heat Shield PVLP-BEK Brick Kit Figure 16.6 PVLP-SLP Vent Components Heat & Glo • SLR-D • 2333-900 Rev. F • 9/17...
  • Page 70 (127 mm) 13-7/8 in. (352 mm) DVP-BEK2 DVP-HPC Cap Brick Extension COAXIAL to COLINEAR VENTING LINK-DV30B DVP-2SL DV-46DVA-GCL Flex Liner Kit Adapter Coaxial/Colinear Appliance Connector Figure 16.7 Vent Components Heat & Glo • SLR-D • 2333-900 Rev. F • 9/17...
  • Page 71: Service Parts

    5941237, 6006743, 6019099, 6053165, 6145502, 6374822, 6484712, 6601579, 6769426, 6863064, 7077122, 7098269, 7258116, 7470729, 8147240 or other U.S. and foreign patents pending. 2000-945C Printed in U.S.A. - Copyright 2017 Heat & Glo • SLR-D • 2333-900 Rev. F • 9/17...

This manual is also suitable for:

Slr-d cosmo

Table of Contents