Electrical Information

A. General Information

WARNING! Risk of Shock or Explosion! DO NOT wire
220/240 VAC to the valve or to the appliance wall switch.
Incorrect wiring will damage controls.
• Wire the appliance junction cord to unswitched 220/240
VAC. This is required for proper operation of the
appliance.
• A 220/240 VAC circuit for this product must be protected
with ground-fault circuit-interrupter protection, in
compliance with the applicable electrical codes, when
it is installed in locations such as in bathrooms or near
sink.
• Low voltage and 220/240 VAC voltage cannot be shared
within the same wall box.
Electrical Service and Repair
WARNING! Risk of Shock! Label all wires prior to dis-
connection when servicing controls. Wiring errors can
cause improper and dangerous operation. Verify proper
operation after servicing.
WARNING! Risk of Shock! Replace damaged wire with
type 105 ºC rated wire. Wire must have high temperature
insulation.
Valve/Control Access
The valve/control cavity is accessible, by removing two
screws located in the lower right and left corners of the
fireplace opening.
Once finish material has been installed access to the
valve/control cavity is limited to access through the fire-
box, see Section 9.C.
Accessories Requirements
• This appliance may be used with a wall switch, wall
mounted thermostat and/or a remote control.
Wiring for optional Hearth & Home Technologies approved
accessories should be done now to avoid reconstruction.
Follow instructions that come with those accessories.
38
Heat & Glo • SLR-X-AU Installation Manual • 2493-980 Rev. B • 12/17
Junction Cord Installation
WARNING! Risk of Shock! Label all wires prior to dis-
connection when servicing controls. Wiring errors can
cause improper and dangerous operation. Verify proper
operation after servicing.
Note: The lower cover panel is removable if finish mate-
rial has not been installed.
WARNING! Risk of Shock! Replace damaged wire with
type 105 °C rated wire. Wire must have high temperature
insulation.
NOTE: Appliance shown
without glass installed.
BOTTOM PANEL SCREW LOCATIONS
Figure 8.1 Lower Access Panel Location
Gas Valve
Backup Battery Control Module
Figure 8.2 Gas Valve, Backup Battery, Control Module &
AUX300CE