Lock the clean unit (right)

Lock the clean unit (right)
Introduction
This procedure is only intended for key operators who received the special maintenance training.
When to do
After you replaced the cleaners
you accidentally forgot to lock a clean unit after you replaced the cleaners, the machine will
detect this during the initialization. Then the operator panel will display this maintenance task.
Required tools
Service key (supplied with the machine)
Socket wrench 10 (supplied with the machine)
Procedure
1. Press [Start] to start the maintenance wizard.
At the start of the procedure, the machine is turned off.
CAUTION
Wait until the machine is turned off. Opening the doors too soon can possibly cause
injury.
2. Use socket wrench 10 to loosen the bolt of the front doors (2).
3. Open the front doors (3).
[35] Open the front doors
36
Chapter 2 - Maintenance tasks - Level 1
Replace the cleaners on page
14, you must restart the machine. If
Océ VarioPrint 6000 line