House Air

It is the customer's responsibility to provide compressed air to the LightJet
Figure 2-6, a 6.35 mm (1/4") hose (no fittings required) is required to deliver compressed air to
the printer.
The air supply must meet the following minimum requirements:
Volume flow - 1 CFM
Pressure - 70 psi regulated
Air supplied to the machine must pass through an air preparation unit that contains the
following:
Air filter - 5.0 micron element complete with an auto drain
Coalescing filter - 99.97% coalescing efficiency with an auto drain
Regulator - complete with pressure gauge
Levered (¼ turn) ball valve (optional) - turns the air off
NOTE
If anything other than clean dry air is sent to the air bearings in the micropositioner,
the air ports within the micropositioner can become clogged. There is no way to repair
this in the field and the entire LightJet must be returned to the factory for repair.
45572-I
see copyright, disclosure, use and duplication information on pg. iii

Figure 2-6 Right side connections.

System Requirements
6.35 mm (1/4") hose
®