Assembly and Installation Notes
4

Connection and terminal description of the DFP21B option

4.4
Connection and terminal description of the DFP21B option
Part number
Front view of DFP21B
DFP21B
RUN
BUS
FAULT
5
9
6
1
X30
0 1
0
2
1
2
2
2
3
2
4
2
5
2
6
2
AS
ADDRESS
59110AXX
Front view of
®
MOVITRAC
B, DFP21B
and UOH11B
H1
H2
X24
58129axx
20
PROFIBUS interface type DFP21B option: 824 240 2
The "PROFIBUS interface type DFP21B" option is only possible in conjunction with
®
MOVIDRIVE
MDX61B, not with MDX60B.
The DFP21B option must be plugged into the fieldbus slot.
Description
RUN: PROFIBUS operation
LED (green)
BUS FAULT: PROFIBUS error
LED (red)
ADDRESS: DIP switch for set-
ting the PROFIBUS station
address
X30: PROFIBUS connection
Description
LED H1 (red)
LED H2 (green)
X24 X terminal
DIP
switches
Function
Terminal
Indicates that the bus electronics are operating
correctly.
Indicates PROFIBUSDP error.
0
2
Significance: 1
1
2
Significance: 2
2
2
Significance: 4
3
2
Significance: 8
4
2
Significance: 16
5
2
Significance: 32
6
2
Significance: 64
AS
Autosetup for gateway operation
X30:1
N.C.
X30:2
N.C.
X30:3
RxD/TxD-P
X30:4
CNTR-P
X30:5
DGND (M5V)
X30:6
VP (P5V/100 mA)
X30:7
N.C.
X30:8
RxD/TxD-N
X30:9
DGND (M5V)
Function
System error (only for gateway functions)
Reserved
RS-485 interface for diagnostics via PC and
®
MOVITOOLS
(only applies to MOVITRAC
Manual – DFP21B PROFIBUSDP-V1 Fieldbus Interface
MotionStudio
®
B)

Hide quick links: