Mounting A 5U Or 10U Extension; Installing Tie Bars - HP StorageWorks MSL6000 Series Reference Manual

Pass-through mechanism, tape library
Hide thumbs Also See for StorageWorks MSL6000 Series:
Table of Contents

Advertisement

Figure 17

Mounting a 5U or 10U extension

c. Attach the large tie bar (beveled edge to the inside corner of the PTM base unit and
extension) using four mounting screws (see
Figure 18

Installing tie bars

10.Repeat
step 9
for each extension.
11.Remove the bottom stop standoff from the PTM base unit and then attach it to the corresponding
mounting hole (see
12.Secure the belt tensioner ramp and idler pulley to the extension using the two previously
removed screws (see
13.Secure the belt tensioner ramp and idler pulley springs using the two previously removed screws
(see
Figure 16
on page 26).
Figure
18) in the last unit of the extended PTM.
Figure 16
on page 26).
MSL6000 series pass-through mechanism reference guide
Figure
18).
27