Library Installation, 10U Models (9000 Rack Enclosure Shown) - HP StorageWorks MSL6000 Series Reference Manual

Pass-through mechanism, tape library
Hide thumbs Also See for StorageWorks MSL6000 Series:
Table of Contents

Advertisement

CAUTION:
Do not apply power to either library. Attempting to connect or disconnect a PTM base
unit to a library that has power applied can damage the library and the PTM base unit PCB.
Figure 10

Library installation, 10U models (9000 rack enclosure shown)

NOTE:
After installing the libraries, secure each one to the rack enclosure using its front bezel
thumbscrews.
2.
Remove the blank panels or drive shoe assembly 1 and 3 from the bays adjacent to the PTM
cover plate openings of each library (see
a. Loosen the captive retaining screws at the top and bottom of the blank panels or drive shoe
assembly 1 and 3.
b. Remove the blank panels or pull straight back on the drive shoe assembly 1 and 3 handles to
unplug them.
Figure 11
on page 22).