APPENDIX B
Table B–9: MODBUS MEMORY MAP (Sheet 39 of 60)
ADDR
REGISTER NAME
9996
Reserved (10 items)
9A00
Teleprotection Input 1-n Default States (16 items)
9A10
Teleprotection Input 2-n Default States (16 items)
9A20
Teleprotection Output 1-n Operand (16 items)
9A40
Teleprotection Output 2-n Operand (16 items)
Teleprotection Channel Tests (Read Only)
9AA0
Teleprotection Channel 1 Status
9AA1
Teleprotection Channel 1 Number of Lost Packets
9AA2
Teleprotection Channel 2 Status
9AA3
Teleprotection Channel 2 Number of Lost Packets
9AA4
Teleprotection Network Status
9AAF
Teleprotection Channel 1 Input States
9AB0
Teleprotection Channel 2 Input States
9AC0
Teleprotection Input 1 States, 1 per register (16 items)
9AD0
Teleprotection Input 2 States, 1 per register (16 items)
VT Fuse Failure (Read/Write Setting) (6 modules)
A09A
VT Fuse Failure Function
A09B
VT Fuse Failure Neutral Wire Open Function
A09C
VT Fuse Failure Neutral Wire Open 3rd Harmonic Pickup
A09D
...Repeated for module number 2
A0A0
...Repeated for module number 3
A0A3
...Repeated for module number 4
A0A6
...Repeated for module number 5
A0A9
...Repeated for module number 6
A0AC
VTFF x V0 3rd harmonic
Selector switch actual values (read only)
A210
Selector switch 1 position
A211
Selector switch 2 position
Selector switch settings (read/write, 2 modules)
A280
Selector 1 Function
A281
Selector 1 Range
A282
Selector 1 Timeout
A283
Selector 1 Step Up
A285
Selector 1 Step Mode
A286
Selector 1 Acknowledge
A288
Selector 1 Bit0
A28A
Selector 1 Bit1
A28C
Selector 1 Bit2
A28E
Selector 1 Bit Mode
A28F
Selector 1 Bit Acknowledge
A291
Selector 1 Power Up Mode
A292
Selector 1 Target
A293
Selector 1 Events
A294
Reserved (10 items)
A29E
...Repeated for Selector 2
Digital Counter (Read/Write Setting) (8 modules)
A300
Digital Counter 1 Function
A301
Digital Counter 1 Name
A307
Digital Counter 1 Units
A30A
Digital Counter 1 Block
A30C
Digital Counter 1 Up
A30E
Digital Counter 1 Down
A311
Digital Counter 1 Preset
GE Multilin
RANGE
0 to 1
0 to 3
0 to 3
0 to 4294967295
0 to 4294967295
0 to 2
0 to 65535
0 to 2
0 to 65535
0 to 2
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 3
0 to 999999.999
1 to 7
1 to 7
0 to 1
1 to 7
3 to 60
0 to 4294967295
0 to 1
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 1
0 to 4294967295
0 to 2
0 to 2
0 to 1
---
0 to 1
---
---
0 to 4294967295
0 to 4294967295
0 to 4294967295
–2147483647 to
2147483647
D30 Line Distance Protection System
B.4 MEMORY MAPPING
UNITS
STEP
FORMAT
---
---
F001
---
1
F086
---
1
F086
---
1
F300
---
1
F300
---
1
F134
---
1
F001
---
1
F134
---
1
F001
---
1
F134
---
1
F500
---
1
F500
---
1
F108
---
1
F108
---
1
F102
---
1
F102
pu
0.001
F001
V
0.001
F060
---
1
F001
---
1
F001
---
1
F102
---
1
F001
s
0.1
F001
---
1
F300
---
1
F083
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F083
---
1
F300
---
1
F084
---
1
F109
---
1
F102
---
1
F001
---
1
F102
---
---
F205
---
---
F206
---
1
F300
---
1
F300
---
1
F300
---
1
F004
DEFAULT
0
0 (Off)
0 (Off)
0
0
1 (OK)
0
1 (OK)
0
2 (n/a)
B
0
0
0 (Off)
0 (Off)
0 (Disabled)
0 (Disabled)
100
0
0
1
0 (Disabled)
7
50
0
0 (Time-out)
0
0
0
0
0 (Time-out)
0
0 (Restore)
0 (Self-reset)
0 (Disabled)
0
0 (Disabled)
"Counter 1"
(none)
0
0
0
0
B-47