GE D30 series Instruction Manual page 482

Line distance protection system. ur series
Hide thumbs Also See for D30 series:
Table of Contents

Advertisement

B.4 MEMORY MAPPING
Table B–9: MODBUS MEMORY MAP (Sheet 24 of 60)
ADDR
REGISTER NAME
5798
...Repeated for RTD Input 47
57AC
...Repeated for RTD Input 48
Flexlogic Timers (Read/Write Setting) (32 modules)
5800
FlexLogic Timer 1 Type
5801
FlexLogic Timer 1 Pickup Delay
5802
FlexLogic Timer 1 Dropout Delay
5803
Reserved (5 items)
5808
...Repeated for FlexLogic Timer 2
5810
...Repeated for FlexLogic Timer 3
5818
...Repeated for FlexLogic Timer 4
B
5820
...Repeated for FlexLogic Timer 5
5828
...Repeated for FlexLogic Timer 6
5830
...Repeated for FlexLogic Timer 7
5838
...Repeated for FlexLogic Timer 8
5840
...Repeated for FlexLogic Timer 9
5848
...Repeated for FlexLogic Timer 10
5850
...Repeated for FlexLogic Timer 11
5858
...Repeated for FlexLogic Timer 12
5860
...Repeated for FlexLogic Timer 13
5868
...Repeated for FlexLogic Timer 14
5870
...Repeated for FlexLogic Timer 15
5878
...Repeated for FlexLogic Timer 16
5880
...Repeated for FlexLogic Timer 17
5888
...Repeated for FlexLogic Timer 18
5890
...Repeated for FlexLogic Timer 19
5898
...Repeated for FlexLogic Timer 20
58A0
...Repeated for FlexLogic Timer 21
58A8
...Repeated for FlexLogic Timer 22
58B0
...Repeated for FlexLogic Timer 23
58B8
...Repeated for FlexLogic Timer 24
58C0
...Repeated for FlexLogic Timer 25
58C8
...Repeated for FlexLogic Timer 26
58D0
...Repeated for FlexLogic Timer 27
58D8
...Repeated for FlexLogic Timer 28
58E0
...Repeated for FlexLogic Timer 29
58E8
...Repeated for FlexLogic Timer 30
58F0
...Repeated for FlexLogic Timer 31
58F8
...Repeated for FlexLogic Timer 32
Phase Time Overcurrent (Read/Write Grouped Setting) (6 modules)
5900
Phase Time Overcurrent 1 Function
5901
Phase Time Overcurrent 1 Signal Source
5902
Phase Time Overcurrent 1 Input
5903
Phase Time Overcurrent 1 Pickup
5904
Phase Time Overcurrent 1 Curve
5905
Phase Time Overcurrent 1 Multiplier
5906
Phase Time Overcurrent 1 Reset
5907
Phase Time Overcurrent 1 Voltage Restraint
5908
Phase TOC 1 Block For Each Phase (3 items)
590F
Phase Time Overcurrent 1 Target
5910
Phase Time Overcurrent 1 Events
5911
Reserved (3 items)
5914
...Repeated for Phase Time Overcurrent 2
5928
...Repeated for Phase Time Overcurrent 3
593C
...Repeated for Phase Time Overcurrent 4
B-32
RANGE
0 to 2
0 to 60000
0 to 60000
0 to 65535
0 to 1
0 to 5
0 to 1
0 to 30
0 to 16
0 to 600
0 to 1
0 to 1
0 to 4294967295
0 to 2
0 to 1
0 to 1
D30 Line Distance Protection System
APPENDIX B
UNITS
STEP
FORMAT
---
1
F129
0 (millisecond)
---
1
F001
---
1
F001
---
1
F001
---
1
F102
---
1
F167
---
1
F122
pu
0.001
F001
---
1
F103
0 (IEEE Mod Inv)
---
0.01
F001
---
1
F104
0 (Instantaneous)
---
1
F102
---
1
F300
---
1
F109
---
1
F102
---
1
F001
DEFAULT
0
0
0
0 (Disabled)
0 (SRC 1)
0 (Phasor)
1000
100
0 (Disabled)
0
0 (Self-reset)
0 (Disabled)
0
GE Multilin

Advertisement

Table of Contents
loading

Table of Contents