GE D30 series Instruction Manual page 470

Line distance protection system. ur series
Hide thumbs Also See for D30 series:
Table of Contents

Advertisement

B.4 MEMORY MAPPING
Table B–9: MODBUS MEMORY MAP (Sheet 12 of 60)
ADDR
REGISTER NAME
351C
RTD Input 45 Value
351D
RTD Input 46 Value
351E
RTD Input 47 Value
351F
RTD Input 48 Value
Ohm Input Values (Read Only) (2 modules)
3520
Ohm Inputs 1 Value
3521
Ohm Inputs 2 Value
Expanded Direct Input/Output Status (Read Only)
3560
Direct Device States, one per register (8 items)
3570
Direct Input States, one per register (96 items)
B
Radius Configuration (Read/Write Setting)
3735
Undefined
3737
Undefined
3738
Undefined
3739
Undefined
373B
Undefined
373D
Undefined
373F
Undefined
3740
Undefined
3741
Undefined
3742
Undefined
3743
Undefined
PTP Basic Configuration (Read/Write Setting)
3750
PTP Strict Power Profile
3751
PTP Domain Number
3752
PTP VLAN Priority
3753
PTP VLAN ID
3754
Undefined (2 items)
PTP Port Configuration (Read/Write Setting) (3 modules)
3756
PTP Port x Function
3757
Port x Path Delay Adder
3758
Port x Path Delay Asymmetry
3759
...Repeated for module number 2
375C
...Repeated for module number 3
Real Time Clock Synchronizing Actuals (Read Only)
375F
RTC Sync Source
3760
PTP GrandMaster ID
3764
Real Time Clock Accuracy
3766
PTP Port 1 State (3 items)
3769
RTC Offset
376B
PTP - IRIG-B Delta
Real Time Clock Synchronizing FlexAnalogs (Read Only)
376D
PTP - IRIG-B Delta FlexAnalog
Field Units (Read/Write Setting) (8 modules)
3800
Field Unit 1 ID
3806
Field Unit 1 Function
3807
Field Unit 1 Type
3808
Field Unit 1 Serial Number
380E
Field Unit 1 Port
380F
...Repeated for Field Unit 2
381E
...Repeated for Filed Unit 3
382D
...Repeated for Filed Unit 4
383C
...Repeated for Filed Unit 5
384B
...Repeated for Filed Unit 6
B-20
RANGE
-32768 to 32767
-32768 to 32767
-32768 to 32767
-32768 to 32767
0 to 65535
0 to 65535
0 to 1
0 to 1
0 to 4294967295
1 to 65535
1 to 65535
0 to 4294967295
0 to 65535
0 to 65535
---
1 to 65535
0 to 9999
0 to 9999
---
0 to 1
0 to 255
0 to 7
0 to 4095
0 to 1
0 to 1
0 to 60000
-1000 to 1000
0 to 5
0 to 100
0 to 999999999
0 to 4
0 to 999999999
-500000000 to 500000000
-262143 to 262143
0 to 1
0 to 1
0 to 3
0 to1
1 to 4
D30 Line Distance Protection System
APPENDIX B
UNITS
STEP
FORMAT
°C
1
F002
°C
1
F002
°C
1
F002
°C
1
F002
Þ
1
F001
Þ
1
F001
---
1
F155
---
1
F108
---
1
F003
---
1
F001
---
1
F001
---
1
F003
---
1
F001
---
1
F001
---
1
F619
0 (EAP-TTLS)
---
1
F001
sec
1
F001
---
1
F001
---
---
F002
---
1
F102
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F102
ns
1
F001
ns
1
F002
---
1
F624
--
1
F073
ns
1
F003
--
1
F625
ns
1
F004
ns
1
F004
---
1
F004
---
1
F205
---
1
F102
---
1
F243
---
1
F205
"000000000000"
---
1
F001
DEFAULT
0
0
0
0
0
0
0 (Offline)
0 (Off)
56554706
1812
1813
56554706
1812
1813
2910
10
3
(none)
1 (Enabled)
0
4
0
0
0 (Disabled)
0
0
0 (none)
0
0
0 (Disabled)
0
0
0
"U1"
0 (Disabled)
0 (CC-05)
1
GE Multilin

Advertisement

Table of Contents
loading

Table of Contents