B
W A R N I N G
!
Hazard of explosive gas mixture. Keep sparks, flame, and smoking material away from
battery.
Always wear safety glasses when working with batteries.
Battery fluid is highly corrosive. Thoroughly rinse away any spilled fluid with clean water.
Always replace batteries with UpRight batteries or manufacturer approved replacements
weighing 28 kg. (62 lbs.) each.
W A R N I N G
!
Charge batteries in a well ventilated area.
Do not charge batteries when the work platform is in an area containing sparks or
flames.
Permanent damage to batteries will result if batteries are not immediately recharged
after discharging.
Never leave charger operating unattended for more than two days.
Never disconnect cables from batteries when charger is operating.
Keep charger dry.
Never operate machine while batteries are being charged.
NOTE:
Charger circuit must be
used with a GFI (Ground Fault
Circuit Interrupt) outlet.
NOTE:
Do not operate the
machine while the charger is
plugged in.
SL20
M
ATTERY
AINTENANCE
• Check battery fluid level daily, especially if work platform is being used in a warm, dry climate.
• If electrolyte level is lower than 10 mm (3/8 in.) above plates, add distilled water ONLY. Do not
use tap water with high mineral content, as it will shorten battery life.
• The battery and cables should be inspected regularly for signs of cracks in the case, electro-
lyte leakage and corrosion of the terminals. Inspect cables for worn spots or breaks in the
insulation and for broken cable terminals. Keep terminals and tops of batteries clean.
• Refer to the Service Manual to extend battery life and for complete service instructions.
B
C
ATTERY
HARGING

Figure 2-7: Power Module

Charge batteries at end of each work
shift or sooner if batteries have been
discharged.
1. Check battery fluid level. If electrolyte level is lower than 10 mm (3/8 in.) above plates add
distilled water only.
2. Connect extension cord to charger plug at end of left module. Connect extension cord 1.5
mm² (12 gauge)minimum conductor diameter; 15m (50 ft.) maximum length) to properly
grounded outlet of correct voltage and frequency.
3. Charger turns on automatically after a short delay.
Operation - 2.6 - Maintenance
Remove to check fluid level
Battery Charger
Page 2-7