4. Parameter
Outline of PANATERM
With the PANATERM
1) Setup and storage of parameters, and writing to the memory (EEPROM).
2) Monitoring of I/O and pulse input and load factor.
3) Display of the present alarm and reference of the error history.
4) Data measurement of the wave-form graphic and bringing of the stored data.
5) Normal auto-gain tuning
6) Frequency characteristic measurement of the machine system.
Setup with the Console
Mode Switching Button
1) Monitor mode
2) Parameter setup mode
3) EEPROM write mode
®
, you can execute the followings.
®
Display LED (6-digit)
All of LED will flash when error occurs, and switch to
error display screen.
Displays ID No. (address) of selected driver (in 2 digits).
The value set in Pr00(address) is ID No. Parameter No.
is displayed (2 digits) at parameter setup mode.
Press this to shift the digit for data change.
Press these to change data or execute selected action
of parameter.
Numerical value increases by pressing ,
decreases by pressing
SET Button
Press this to shift each mode which is selected by
mode switching button to EXECUTION display.
Press this to switch 6 kinds of mode.
4) Normal auto-gain tuning mode
5) Auxiliary function mode
6) Copy mode
.
– B28 –
,