3. System Configuration and Wiring

Wiring to the connector, X7

The connector X7 of the front panel is for monitor output.
 Analogue output : 2 systems
In both cases, it is possible to switch the output signal by setting parameters.
Connector X7
Manufacturer's part No.:
530140610
6
1
Manufacturer:
Japan Molex Inc.
X7
Connector
Application
Symbol
Analogue monitor
AM1
output 1
Analogue monitor
AM2
output 2
Signal ground
GND
NC
NC
NC
Remarks
X1 to X7 are used for the secondary circuit. To connect these terminals to the primary
power supply (particularly, the 24 VDC power supply for brake), insulation is required.
Do not connect these terminals to the same power supply.
Output circuit
1 kΩ AM1
1
Measuring
1 kΩ AM2 2
instrument
GND 3
Contents
Pin No.
• Output the analogue signal for
1
monitor.
• The amplitude of the output signal is
±10 V.
• Output impedance is 1 kΩ. When
2
connecting a measuring instrument,
check its input circuit for impedance
matching.
3
Connected to ground of control circuit.
4
Do not connect.
5
Do not connect.
6
Do not connect.
− B28 −

4. Parameter

Outline / Setup / Connection

Outline of Parameter
This driver is equipped with various parameters to set up its characteristics and func-
tions. This section describes the function and purpose of each parameter. Read and
comprehend very well so that you can adjust this driver in optimum condition for your
running requirements.
• You can refer and set up the parameter with either one of the following.
1) front panel of the driver
2) combination of the setup support software, "PANATERM" and PC.
Setup with the Front Panel
6
1
X7
Shifting of the digit for data
changing to higher digit.
X7
Output connector for monitor
Display LED (6-digit)
Switch to error display screen when error
occurs, and LED will flash (about 2 Hz).
LED will flash slowly (about 1 Hz) when
warning occurs.
Mode switching button
(valid at SELECTION display)
Press this to switch 4 kinds of mode.
1) Monitor Mode
2) Parameter Set up Mode
3) EEPROM Write Mode
4) Auxiliary Function Mode
SET Button (valid at any time)
Press this to switch SELECTION and
EXECUTION display.
Press these to change display and data,
select parameters and execute actions.
(Change/Selection/Execution is valid to the
digit which decimal point flashes.)
Numerical value increases by pressing,
decreases by pressing
.
− B29 −
,