4. Parameter
Parameters for Adjustment of Time Constant for Gains and Filters
Parameter
Set up of parameter
No.
(Pr
)
18
2nd gain of position loop
19
2nd gain of velocity loop
1A
2nd Time constant of velocity loop integration
1B
2nd filter of velocity detection
1C
2nd torque filter time constant
1D
1st notch frequency
1E
Selection of 1st notch width
1F
(For manufacturer's use)
27
Setup of instantaneous velocity observer
28
2nd notch frequency
29
Selection of 2nd notch width
2A
Selection of 2nd notch depth
2B
1st damping frequency
2C
Setup of 1st damping filter
2D
2nd damping frequency
2E
Setup of 2nd damping filter
Parameters for Auto-Gain Tuning
Parameter
Set up of parameter
No.
(Pr
)
20
Inertia ratio
21
Setup of real-time auto-gain tuning mode
22
Mechanical stiffness at real-time auto-gain tuning
23
Setup of adaptive filter mode
24
Selection of damping filter switching
25
Setup of action at normal mode auto-gain tuning
26
Setup of software limit
2F*2
Adaptive filter frequency
*2 this parameter will be automatically set up when the adaptive filter is validated (Pr23,
"Setup of adaptive filter mode" is "1", and you cannot set this up at your discretion.
Set up Pr23, "Setup of adaptive filter mode" to "0" (invalid) to clear this parameter.
* In this documentation, each mode is represented by the following symbols
P : Position control, S : Velocity control, T : Torque control, F : Full-closed control,
P/S : Position (1st),/Velocity (2nd) control, P/T : Position (1st)/Torque (2nd) control,
S/T : Velocity (1st)/Torque (2nd) control.
Default
Range
A to
C-frame
0 to 3000
<73> <38>
1 to 3500
<35> <18>
1 to 1000
<1000>
0 to 5
<0>
0 to 2500
<65> <126>
100 to 1500
1500
0 to 4
2
0 to 1
<0>
100 to 1500
1500
0 to 4
2
0 to 99
0
0 to 2000
0
–200 to 2000
0
0 to 2000
0
–200 to 2000
0
Default
Range
A to
C-frame
0 to 10000
<250>
0 to 7
1
0 to 15
4
0 to 2
1
0 to 2
0
0 to 7
0
0 to 1000
10
0 to 64
0
– B32 –
Related control
Unit
D to
mode
F-frame
1/s
P, F
Hz
ms
0.01ms
Hz
P, S
Hz
0.1Hz
P, F
P, F
0.1Hz
P, F
P, F
Related control
Unit
D to
mode
F-frame
%
1
P, S, F
P, F
0.1rev
P, F
P, S, F
all
all
all
all
all
all
all
all
all
all
all
all
all

Advertisement