12. Using the electric drill with #26 drill bit; drill 2 holes
into the left side of the hopper. Add two screws to
secure shroud assembly to the appliance (Figure
21.1).
Figure 21.1
13. Attach appropriate the top vent adapter; either 3
inch or 4 inch depending on size of vent pipe using
for your application. Attach this to the top of Rear
Shroud Top Vent (Figures 21.2 and 21.3).
Figure 21.2
Figure 21.3
October 9, 2017
Drill these 2
holes
Verify gasket is installed
between adapters
7014-285A
B. Outside Air Kit Instructions
NOTE: A Quadra-Fire outside air kit; 811-0872, is available
through your Quadra-Fire Dealer to be used as a the out-
side air option, but is required for mobile home installations.
See page 26 Section 7 Mobile Home Installation for more
details.
Parts need from the kit: 1 piece of flex hose, 2 hose
clamps, trim ring, and 1 termination cap assembly See
Figure 21.5 and 8 screws.
Tools Needed: Phillips head screw driver; hole saw or jig
saw.
1. Measure distance from floor to air vent opening in appli-
ance and mark location on wall.
2. Use saw to cut opening in wall. Cut a 2-1/2 to 3 inches
(64-76mm) opening on inside wall and a 3 to 3-1/2 inch
(76-89mm) opening on outside of house.
3. Use hose clamp to secure flex pipe to collar assembly.
4. Slide trim ring over flex pipe and run pipe through wall.
5. Attach hose to outside termination cap with second hose
clamp.
6. Secure termination cap to outside surface.
7. Secure trim ring to interior wall.
CAUTION
Never draw outside combustion air from:
Wall, floor or ceiling cavity
Enclosed space such as an attic or garage
Attach hose clamp to
intake air collar
Figure 21.4
Flex Hose
Hose Clamp
Collar
Assembly
Figure 21.5 Outside Air Kit, 811-0872
CB1200 Pellet Insert
Outside air
flex pipe
Trim Ring
Hose Clamp
Termination
Cap Assembly
21